Document IIF

Procédé innovant d'optimisation de la charge pour les systémes de refroidissement à tubes capillaires.

An innovative charge optimization process for capillary tube based cooling systems.

Auteurs : BOENG J., MELO C.

Type d'article : Article de la RIF

Résumé

In the first part of this work an experimental apparatus was designed and constructed to map the energy consumption of a household refrigerator subjected to several combinations of refrigerant charge and expansion restriction. In the second part, the expansion restriction imposed by the pair metering valve-capillary tube was converted into an equivalent tube diameter applying two different procedures: dry nitrogen flow and mathematical modeling. An empirical correlation to estimate the energy consumption based on the capillary tube inner diameter and refrigerant charge was also developed and used during the minimization process. Different strategies were also explored in order to reduce the amount of experiments to a minimum. It was found that at least 14 data points, collected with three different refrigerant charges, are required to ensure the convergence of the energy consumption minimization process.

Documents disponibles

Format PDF

Pages : 202-209

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : An innovative charge optimization process for capillary tube based cooling systems.
  • Identifiant de la fiche : 30027710
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
  • Date d'édition : 10/2020
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.05.005

Liens


Voir d'autres articles du même numéro (50)
Voir la source