Propriétés thermodynamiques d'un frigorigène de remplacement immédiat R-SP34E.

[In Japanese. / En japonais.]

Auteurs : KAYUKAWA Y., HONDO T., WATANABE K.

Type d'article : Article

Résumé

This paper reports the first sets of measured data including 7 dew- and bubble-point pressures and 73 gas-phase PVT properties in the extensive range of temperatures 300-380 K, pressures 0.1-5.2 MPa, and densities up to around the critical density obtained by employing the Burnett apparatus. In order to complement and confirm the reliability of the measurements made, thermodynamic models including a dew-point pressure correlation and a truncated virial equation of state were originally developed in this study. The models were confirmed to exhibit excellent reproducibility of the measurements. By presenting this reliable thermodynamic model, systematic information about the thermodynamic properties of R-SP34E is provided in this paper.

Détails

  • Titre original : [In Japanese. / En japonais.]
  • Identifiant de la fiche : 2002-2816
  • Langues : Japonais
  • Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 3
  • Date d'édition : 2001
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (30)
Voir la source