This work evaluates R-454C, R-459B, R-457A and R-455A as R-404A low-GWP substitutes in a stand-alone commercial refrigeration system for fresh product under ISO 23953-2. System is tested with and with- out receiver. Charge was optimized based on energy consumption tests in climatic chamber. A significant increment of the evaporating temperature of the new mixtures has been observed, which mitigate the negative effects associated to the large glide. Operation is compatible with R-404A for this system, offer- ing energy consumption reductions for optimized charges without receiver of: 2.07% with R-454C, 10.76% with R-459B, 10.48% with R-457A and 2.95% R-455A. Energy consumption reductions with receiver are of 2.45% with R-454C, 11.55% with R-459B, 10.69% with R-457A and 2.9% with R-455A. In most of the cases the optimum refrigerant charge was below R-404A one. It is concluded that R-404A low-GWP substitutes can reduce refrigerant charge and improve energy performance in relation to R-404A.
Documents disponibles
Format PDF
Pages : 133-143
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : R-454C, R-459B, R-457A and R-455A as low-GWP replacements of R-404A: Experimental evaluation and optimization.
- Identifiant de la fiche : 30026820
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Date d'édition : 10/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.06.013
Liens
Voir d'autres articles du même numéro (54)
Voir la source
Indexation
-
Thèmes :
Mesures thermodynamiques;
HFC;
Supermarchés, meubles de vente;
Mélanges - Mots-clés : Thermodynamique; R454C; Application commerciale; Faible GWP; R459b; R457a; R455A; Substitut; Essai; Charge en frigorigène
-
Experimental performance evaluation for a carbo...
- Auteurs : BOCCARDI G., CALABRESE N., CELATA G. P., et al.
- Date : 05/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 54 - n. 2
Voir la fiche
-
Energy impact of the Internal Heat Exchanger in...
- Auteurs : CABELLO R., SÁNCHEZ D., LLOPIS R., ANDREU-NACHER A., CALLEJA-ANTA D.
- Date : 05/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 137
- Formats : PDF
Voir la fiche
-
Ensayos de nuevas alternativas de bajo GWP al R...
- Auteurs : MINOR B., GERSTEL J.
- Date : 09/2014
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 42 - n. 472
- Formats : PDF
Voir la fiche
-
TEWI analysis of a stand-alone refrigeration sy...
- Auteurs : LLOPIS R., CALLEJA-ANTA D., MAIORINO A., NEBOT-ANDRÉS L., SÁNCHEZ D., CABELLO R.
- Date : 10/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 118
- Formats : PDF
Voir la fiche
-
R-407H as drop-in of R-404A. Experimental analy...
- Auteurs : LLOPIS R., SÁNCHEZ D., CABELLO R., et al.
- Date : 08/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 80
- Formats : PDF
Voir la fiche