Évaluation expérimentale de la performance d'un système de froid commercial léger au dioxyde de carbone sous conditions transcritiques et sous-critiques.
Experimental performance evaluation for a carbon dioxide light commercial cooling application under transcritical and subcritical conditions.
Auteurs : BOCCARDI G., CALABRESE N., CELATA G. P., et al.
Type d'article : Article
Résumé
CO2 is one of the most interesting non toxic, nor flammable, low GWP natural fluid to be used in applications with a large direct contribution to global warming, such as vending machines. In this paper the results of an experimental investigation on a small capacity, air-forced refrigerating plant working with CO2 are presented. The air inlet temperatures at gas cooler and evaporator were varied between 16 and 31°C and between -25 and 25°C, respectively, to cover the range of temperatures under conditions typical of commercial refrigeration, during quasi-steady operation. The thermodynamic analysis of the system performance was carried on varying independently the pressure at the gas cooler, by overfeeding the liquid receiver to point out the effect of refrigerant charge. The results allow to describe the performance of the system in a map varying the boundary conditions; at the same time the corresponding variations of the thermodynamic cycle, the COP and the mass flow rate are reported.
Détails
- Titre original : Experimental performance evaluation for a carbon dioxide light commercial cooling application under transcritical and subcritical conditions.
- Identifiant de la fiche : 30007845
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 54 - n. 2
- Date d'édition : 05/2013
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2013.02.026
Liens
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente - Mots-clés : Application commerciale; R744; Performance; Experimentation; Charge en frigorigène; CO2
-
Working fluid charge reduction. 2. Supercritica...
- Auteurs : MARCINICHEN J. B., THOME J. R., PEREIRA R. H.
- Date : 05/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 65
- Formats : PDF
Voir la fiche
-
Working fluid charge reduction. 1. CO2 fin-tube...
- Auteurs : MARCINICHEN J. B., THOME J. R., HORN-PEREIRA R.
- Date : 05/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 65
- Formats : PDF
Voir la fiche
-
Thematic file: Integrated CO2 soluti...
- Auteurs : HAFNER A., NEKSÅ P.
- Date : 18/06/2018
- Langues : Anglais
- Formats : PowerPoint
Voir la fiche
-
R-454C, R-459B, R-457A and R-455A as low-GWP re...
- Auteurs : LLOPIS R., CALLEJA-ANTA D., SÁNCHEZ D., et al.
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche
-
Aplicaciones con CO2 en refrigeración comercial.
- Auteurs : SANZ F., FERNÁNDEZ O.
- Date : 09/2015
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 43 - n. 483
- Formats : PDF