Document IIF
Recherche expérimentale des caractéristiques d'explosion des unités intérieures et extérieures d'un conditionneur d'air split fonctionnant au frigorigène R290.
Experimental research on the explosion characteristics in the indoor and outdoor units of a split air conditioner using the R290 refrigerant.
Résumé
Currently, the most common refrigerants used in household split air conditioners are R22 and R410A. Due to environmental concerns, benign options such as R290 (propane) are under consideration as an alternative. However, R290 is flammable, which poses additional fire and explosion risks. The ignition source and location of the leak that may appear within the indoor and outdoor units were analysed. A series of experiments were carried out to better understand the ignition hazard. The explosion characteristics associated with the indoor and outdoor units were studied whereby the overpressure arising from ignition of R290 was measured at different locations. According to the internal volume of indoor and outdoor units, the amount of R290 that should be deposited inside the indoor and the outdoor units is 7 g and 16 g respectively, to form a stoichiometric concentration. The explosion overpressure in the indoor and outdoor units is sufficiently low so as to not damage the air conditioner system. However, if R290 is ignited during the leak, the indoor or outdoor unit will be burned.
Documents disponibles
Format PDF
Pages : 408-417
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental research on the explosion characteristics in the indoor and outdoor units of a split air conditioner using the R290 refrigerant.
- Identifiant de la fiche : 30017821
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 67
- Date d'édition : 07/2016
Liens
Voir d'autres articles du même numéro (36)
Voir la source
Indexation
-
Thèmes :
Conditionnement d'air pour le confort;
Hydrocarbures - Mots-clés : Système split; Conditionneur d'air; R290; Propane; Inflammabilité; Explosion; Experimentation
-
Effect of reaction inhibitor on diesel explosio...
- Auteurs : SAITOH S., HIGASHI T., ITO M., DANG C., HIHARA E., SHITARA Y.
- Date : 03/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 147
- Formats : PDF
Voir la fiche
-
Experimental study on the failure of electronic...
- Auteurs : LI J., DU Y., WU J., LIN J., WANG C.
- Date : 04/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 112
- Formats : PDF
Voir la fiche
-
Indoor leakage test for safety of R-290 split t...
- Auteurs : LI T.
- Date : 04/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Formats : PDF
Voir la fiche
-
Ignition sources at the stage of usage for mini...
- Auteurs : TAMURA K., TAKAICHI K., TAIRA S., BABA A., ITAKURA S., MORI H., MAKINO H.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
R290 leakage hazards assessment of a 1 HP split...
- Auteurs : NING Q., HE G., SUN W., FAN M., LI X., HONG Z.
- Date : 07/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 139
- Formats : PDF
Voir la fiche