Recherche sur la technologie de conversion des fréquences d'un système de conditionnement d'air et de ventilation d'une station de métro.
Research on frequency conversion technology of metro station's ventilation and air-conditioning system.
Résumé
Ventilation and air-conditioning system (VAC) is the most energy-saving potential system in the metro. This paper analyzes the passenger traffic, air-conditioning load and station air supply on the initial, recent and long-term phase of metro station. And it proposes that it is necessary to run chilled-water pumps, air handing unit (AHU) fans and back/exhaust fans with frequency conversion technology (FCT). Then it uses the thermodynamic method to analyze the impact of running chilled-water pumps with FCT. The results show that running chilled-water pumps with FCT can reduce the total power consumption of system, although increases chiller energy consumption. Then the temperature and velocity fields of the platform and station hall are simulated by CFD software according to the variable air volume. And the results show that under the condition of running the VAC system with FCT, temperature and velocity fields distribution are both in the comfortable range. Finally, by taking a typical summer day for example, this paper analyzes the energy savings of chilled-water pumps, AHU fans and back/exhaust fans on the initial, recent and long-term phase, and the calculation results show that the respective total energy savings are 1103.4 kWh, 1064.3 kWh and 926.2 kWh, and the respective total power saving ratio is 73.4%, 71.2% and 59.5%.
Détails
- Titre original : Research on frequency conversion technology of metro station's ventilation and air-conditioning system.
- Identifiant de la fiche : 30011421
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 69 - n. 1-2
- Date d'édition : 08/2014
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2014.04.016
Liens
Voir d'autres articles du même numéro (7)
Voir la source
Indexation
-
Tale of two low-energy designs: comparison of m...
- Auteurs : WALKER C. E., GLICKSMAN L. R., NORFORD L. K.
- Date : 27/01/2007
- Langues : Anglais
- Source : ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
Voir la fiche
-
Geometric optimization on active chilled beam t...
- Auteurs : GUAN Z., WEN C.
- Date : 05/04/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
Voir la fiche
-
Simulación y análisis de la eficiencia energéti...
- Auteurs : PÉREZ-LOMBARD L., VELÁZQUEZ D., GONZÁLEZ R., et al.
- Date : 05/2005
- Langues : Espagnol
- Source : Instalador - n. 419
Voir la fiche
-
Conception du conditionnement d'air pour le pro...
- Auteurs : NIU X., WANG L., HUANG W., et al.
- Date : 05/2008
- Langues : Chinois
- Source : HV & AC - vol. 38 - n. 211
- Formats : PDF
Voir la fiche
-
La maîtrise de l'énergie dans les établissement...
- Date : 2007
- Langues : Français
- Source : IEPF, Fiche tech. PRISME - n. 4
Voir la fiche