Recherche sur les applications d'un échangeur de chaleur à ligne d'aspiration dans un conditionneur d'air au R290 avec tubes de faible diamètre.
Investigation of application of suction line heat exchanger in R290 air conditioner with small diameter tube.
Résumé
The use of small diameter copper tube is an effective way to reduce refrigerant charge for R290 air conditioner, but may reduce system performance. To improve the performance of R290air conditioner with small diameter copper tube, this paper presents an investigation of application of a suction line heat exchanger. A theoretical analysis is proposed to investigate the effect of the suction line heat exchanger on capacity and coefficient of performance, and a simulation based analysis is processed to investigate the effect of suction line heat exchanger on refrigerant charge of condenser. To verify the results of analysis, experiments on a prototypeR290 air conditioner are carried out, and the results show that the suction line heat exchanger improves the cooling capacity by 5.3% and system efficiency by4.5%, and reduces the refrigerant charge by 6%, which agree well with that of the theoretical and simulation based on analysis.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Investigation of application of suction line heat exchanger in R290 air conditioner with small diameter tube.
- Identifiant de la fiche : 30013052
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Autres équipements de conditionnement d'air;
Evaporateurs, condenseurs et autres échangeurs thermiques;
Hydrocarbures;
Efficacité energétique, économie d'énergie - Mots-clés : Aspiration; Conditionneur d'air; Tube; R290; Simulation; Propane; Performance; Charge en frigorigène; Échangeur de chaleur
-
Developing low charge R290 room air conditioner...
- Auteurs : DING G., REN T., et al., WU W.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Experimental study of a novel microchannel heat...
- Auteurs : XU B., WANG Y., CHEN J. P., et al.
- Date : 17/06/2013
- Langues : Anglais
- Source : 4th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Design and analysis of R290 high capacity air t...
- Auteurs : NAVARRO-PERIS E., GONZÁLVEZ-MACIÁ J., CORBERÁN J. M., et al.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Experimental performance study of a small wall ...
- Auteurs : WU J. H., YANG L. D., HOU J.
- Date : 11/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 7
- Formats : PDF
Voir la fiche
-
Retrofit assessment of window air conditioner.
- Auteurs : TENG T. P., MO H. E., LIN H., et al.
- Date : 01/2012
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 32
Voir la fiche