RECHERCHES EXPERIMENTALES SUR LE MELANGE TERNAIRE R22-R124-R152A UTILISE COMME REMPLACANT EN FROID DOMESTIQUE.

EXPERIMENTAL INVESTIGATIONS INTO THE TERNARY BLEND HFC22-124-152A AS A SUBSTITUTE IN DOMESTIC REFRIGERATION.

Auteurs : KUIJPERS L. J. M.

Résumé

LES LUBRIFIANTS POUR LES FRIGORIGENES HFC SONT DIFFICILES A METTRE AU POINT. EN OUTRE, DES INCERTITUDES PERSISTENT QUANT A L'EFFICACITE ENERGETIQUE DU R134A. UN MELANGE TERNAIRE, CONSTITUE DE R22, DE R124 ET DE R152A, A ETE UTILISE COMME REMPLACANT DU R12. LE LUBRIFIANT A UTILISER NE DEVRAIT PAS PRESENTER DE PROBLEMES MAJEURS. L'EFFICACITE ENERGETIQUE DEVRAIT ETRE EGALE OU LEGEREMENT MEILLEURE A CELLE DU R12. DANS L'ARTICLE, ON EFFECTUE UNE VERIFICATION EXPERIMENTALE DU COMPORTEMENT DU MELANGE, SUR UNE SERIE DE CONGELATEURS VERTICAUX. CHACUN DE CES CONGELATEURS EST EQUIPE D'UN TUBE CAPILLAIRE DE PUISSANCE DIFFERENTE. ON A ETUDIE UNE COMPOSITION DU MELANGE -CELLE DETERMINEE DE FACON A CE QU'ELLE PRESENTE LE COP LE PLUS ELEVE -PAR L'UTILISATION D'UN PROGRAMME DE CYCLE EN REGIME STABLE. LA CONCLUSION LA PLUS MARQUANTE EST QUE L'ON OBSERVE UNE CONSOMMATION ENERGETIQUE COMPARABLE POUR LE R12ET LE MELANGE TERNAIRE.

Détails

  • Titre original : EXPERIMENTAL INVESTIGATIONS INTO THE TERNARY BLEND HFC22-124-152A AS A SUBSTITUTE IN DOMESTIC REFRIGERATION.
  • Identifiant de la fiche : 1991-1171
  • Langues : Anglais
  • Date d'édition : 17/07/1990
  • Source : Source : USNC-IIR/Proc. 1990 Refrig. Conf., Purdue Univ./ASHRAE, Purdue CFC Conf./Purdue Univ., Ray W. Herrick Lab., Sch. mech. Eng.
    315-324; 2 fig.; 4 tabl.; 16 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.