Résumé
This paper presents analysis of location of refrigerant inventory and theoretical results of charge reduction in a typical bottle cooler. The original unit was first characterized by determining its capacity, the coefficient of performance (COP), pull-down characteristics and total charge using non-destructive instrumentation. After that the unit was instrumented by insertion of valves to separate main components and allow measurements of the charge in each of them, as well as pressure transducers, mass flow meter and thermocouples. Condenser is found to be the component that retains the most charge. The system was modelled using Engineering Equation Solver (EES) for calculation of performance and charge. Models are fully validated using steady state experimental results. Discussion of the results and direction for the charge reduction is provided.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Refrigerant charge reduction in small commercial refrigeration systems.
- Identifiant de la fiche : 30013412
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Compresseurs;
Evaporateurs, condenseurs et autres échangeurs thermiques;
Transfert de chaleur;
Confinement, réduction de la charge en frigorigène;
Efficacité energétique, économie d'énergie - Mots-clés : Système frigorifique; Application commerciale; Transfert de chaleur; Modélisation; COP; Condenseur; Charge en frigorigène; Distribution; Compresseur; Chute de pression
-
Two-phase pressure drop with non uniform distri...
- Auteurs : LÓPEZ BELCHÍ A., VERA-GARCÍA F., GARCÍA-CASCALES J. R., et al.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche
-
Charge reduction potentials of several refriger...
- Auteurs : PADILLA-FUENTES Y., HRNJAK P.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Prediction of R410A charge amount in a microcha...
- Auteurs : PARK C. Y.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Refrigerant and lubricant charge in AC heat exc...
- Auteurs : JIN S., HRNJAK P.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Refrigerant charge optimization.
- Auteurs : CORBERÁN J. M.
- Date : 25/10/2012
- Langues : Anglais
- Source : RCR 2012. 3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems: Valencia, Spain, October 25-26, 2012.
- Formats : PDF
Voir la fiche