Réduction de la chute de pression et détérioration du transfert de chaleur d’azote pâteux en écoulement dans des canalisations triangulaire et circulaire.

Pressure drop reduction and heat transfer deterioration of slush nitrogen in triangular and circular pipe flows.

Auteurs : OHIRA K., KUROSE K., OKUYAMA J., et al.

Type d'article : Article

Résumé

Slush fluids such as slush hydrogen and slush nitrogen are characterized by superior properties as functional thermal fluids due to their density and heat of fusion. In addition to allowing efficient hydrogen transport and storage, slush hydrogen can serve as a refrigerant for high-temperature superconducting (HTS) equipment using MgB2, with the potential for synergistic effects. In this study, pressure drop reduction and heat transfer deterioration experiments were performed on slush nitrogen flowing in a horizontal triangular pipe with sides of 20 mm under the conditions of three different cross-sectional orientations. Experimental conditions consisted of flow velocity (0.3–4.2 m/s), solid fraction (0–25 wt.%), and heat flux (0, 10, and 20 kW/m2). Pressure drop reduction became apparent at flow velocities exceeding about 1.3–1.8 m/s, representing a maximum amount of reduction of 16–19% in comparison with liquid nitrogen, regardless of heating. Heat transfer deterioration was seen at flow velocities of over 1.2–1.8 m/s, for a maximum amount of deterioration of 13–16%. The authors of the current study compared the results for pressure drop reduction and heat transfer deterioration in triangular pipe with those obtained previously for circular and square pipes, clarifying differences in flow and heat transfer properties. Also, a correlation equation was obtained between the slush Reynolds number and the pipe friction factor, which is important in the estimation of pressure drop in unheated triangular pipe. Furthermore, a second correlation equation was derived between the modified slush Reynolds number and the pipe friction factor, enabling the integrated prediction of pressure drop in both unheated triangular and circular pipes.

Détails

  • Titre original : Pressure drop reduction and heat transfer deterioration of slush nitrogen in triangular and circular pipe flows.
  • Identifiant de la fiche : 30021136
  • Langues : Anglais
  • Source : Cryogenics - vol. 81
  • Date d'édition : 12/2016
  • DOI : http://dx.doi.org/10.1016/j.cryogenics.2016.12.001

Liens


Voir d'autres articles du même numéro (11)
Voir la source