Transfert de chaleur et chute de pression côté calandre lors de l'écoulement de gaz dans un échangeur de chaleur GNL à spirale.

Experimental shell-side heat transfer and pressure drop in gas flow for spiral-wound LNG heat exchanger.

Auteurs : NEERAAS B. O., FREDHEIM A. O., AUNAN B.

Type d'article : Article

Résumé

A test plant has been constructed for measurements of local heat-transfer coefficients and frictional pressure drops on the shell side of spiral-wound LNG heat exchangers. Measurements have been performed with gas flow, liquid film flow and two-phase shear flow. This paper focuses on the measurements and the results from the gas flow measurements. 221 gas flow heat-transfer measurements and 80 gas flow frictional pressure drop measurements have been performed at a Re-number range of 5000-170 000 with nitrogen, methane, ethane and methane/ethane mixture as test fluids.

Détails

  • Titre original : Experimental shell-side heat transfer and pressure drop in gas flow for spiral-wound LNG heat exchanger.
  • Identifiant de la fiche : 2004-1539
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 47 - n. 2
  • Date d'édition : 01/2004

Liens


Voir d'autres articles du même numéro (3)
Voir la source