Résumé
The analysis of a typical container for telecommunication equipment was done to determine the potential for passive cooling. It was specified that throughout the year the temperature inside the container should not exceed 45°C. TRNSYS software package was used to analyze the temperature profile and annual cooling energy based on internal heat loads and outside conditions. Outside conditions were simulated using data for a typical meteorological year in Zagreb and Split, published by the Croatian Meteorological and hydrological service. The results showed considerable potential for natural ventilation and heat rejection through the container envelope. Therefore, it has been proposed to use an envelope made solely of aluminum panels, without the insulation. Furthermore, the proposed construction has ventilation grilles and a chimney to enable passive cooling, as well as an axial fan for periods during which natural ventilation is not sufficient. The results suggest that the proposed solution could completely eliminate the need for a conventional system, despite relatively high internal loads from the telecommunication equipment. The estimated annual electricity consumption for cooling is up to 82 times lower than for a conventional container with a split-system (assumed COP = 3).
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Hibridno hladenje kontejnera za telekomunikacionu opremu.
- Identifiant de la fiche : 30013550
- Langues : Anglais
- Source : Zbornik radova. 45. Medunarodnikongres i izložba o grejanju hladenju i klimatizaciji./ Proceedings. 45th International congress and exhibition on heating, refrigeration and air conditioning (HVAC&R).
- Date d'édition : 03/12/2014
- Notes :
Résumé en serbe
Liens
Voir d'autres communications du même compte rendu (26)
Voir le compte rendu de la conférence
-
Kako smanjiti potrebe za energijom za hladenje ...
- Auteurs : PAUL J.
- Date : 03/12/2008
- Langues : Serbe
- Source : Zbornik radova. 39. Medunarodni kongres o grejanju, hladenju i klimatizaciji.
- Formats : PDF
Voir la fiche
-
Efficienza a carico parziale nei sistemi split:...
- Auteurs : JOPPOLO C. M., MIGLIOLI S., MAGNI F., et al.
- Date : 03/03/2004
- Langues : Italien
- Source : Impianti, edifici, città: integrazione e nuove visioni di progetto e di gestione. 44e Convegno Internazionale AICARR [CD-ROM]./ HVAC&R systems, envelope and urban context: integration and new vision of design and operation. 44th International conference of AICARR [CD-ROM].
Voir la fiche
-
Subcooling system on multiple packaged air cond...
- Auteurs : MAN'O T., TANINO M., ISHII S., et al.
- Date : 20/05/2009
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
Voir la fiche
-
Energy saving performance of the wet-air-condit...
- Auteurs : TATEIWA K., MURASAWA I., WATANABE T.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Low energy cooling strategies.
- Auteurs : IRVING S. J., CONCANNON P. J.
- Date : 01/11/1993
- Langues : Anglais
Voir la fiche