Régulation du débit de gaz continu dans un refroidisseur à tube à pulsation à double entrée.

Control of direct current gas flow in a single-stage double-inlet pulse tube cooler.

Auteurs : WANG C., THUMMES G., HEIDEN C.

Type d'article : Article

Résumé

The use of double-inlet mode in the pulse tube cooler opens up a possibility of direct current gas flow circulating around the regenerator and pulse tube. Numerical analysis shows that effects of direct current flow in a single-stage pulse tube cooler are different in some aspects from that in a 4 K pulse tube cooler. For highest cooler efficiency, direct current flow should be compensated to a small value. Dual valves with reversed asymmetric geometries were used for the double-inlet bypass to control the direct curent flow.

Détails

  • Titre original : Control of direct current gas flow in a single-stage double-inlet pulse tube cooler.
  • Identifiant de la fiche : 1999-3331
  • Langues : Anglais
  • Source : Cryogenics - vol. 38 - n. 8
  • Date d'édition : 08/1998

Liens


Voir d'autres articles du même numéro (4)
Voir la source