Control of direct current gas flow in a single-stage double-inlet pulse tube cooler.

Author(s) : WANG C., THUMMES G., HEIDEN C.

Type of article: Article

Summary

The use of double-inlet mode in the pulse tube cooler opens up a possibility of direct current gas flow circulating around the regenerator and pulse tube. Numerical analysis shows that effects of direct current flow in a single-stage pulse tube cooler are different in some aspects from that in a 4 K pulse tube cooler. For highest cooler efficiency, direct current flow should be compensated to a small value. Dual valves with reversed asymmetric geometries were used for the double-inlet bypass to control the direct curent flow.

Details

  • Original title: Control of direct current gas flow in a single-stage double-inlet pulse tube cooler.
  • Record ID : 1999-3331
  • Languages: English
  • Source: Cryogenics - vol. 38 - n. 8
  • Publication date: 1998/08

Links


See other articles in this issue (4)
See the source