Régulation et optimisation du système frigorifique basées sur le paramètre le plus pertinent.
Control y optimización de un sistema de refrigeración aplicando tecnicas fuzzy adaptativas.
Auteurs : BANDARRA FILHO E. P., MENDOZA O. S. H., GARCIA F. E. M.
Type d'article : Article
Résumé
The refrigeration equipments commonly used in industrial, commercial and residential applications, heat pumps and air conditioning systems are normally operated and controlled by the use of On-Off or PID control. In the last decades the compressor with variable speed is appearing as a good option in terms of energy consumption and electronic expansion valve as well. This paper reports an experimental investigation of a refrigeration system operating with a variable speed compressor and an electronic expansion valve focusing on the reduction of the energy consumption and improvement of the COP. This study worked the use of the adaptive controller hybrid fuzzy (PI fuzzy and PD fuzzy) and using to the inlet of the hybrid-fuzzy control the evaporation temperature calculated with the value of the overall heat transfer coefficient (UA), considered the most relevant parameter of the system. This proportioned the better operation trajectory of the system, where the system operates in the maximum COP regions, improving the performance of the system.
Documents disponibles
Format PDF
Pages : 28-38
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Control y optimización de un sistema de refrigeración aplicando tecnicas fuzzy adaptativas.
- Identifiant de la fiche : 30004761
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 40 - n. 446
- Date d'édition : 04/2012
Liens
- Voir les traductions : Control and optimization of the refrigeration system based on the most relevant parameter.
Voir d'autres articles du même numéro (3)
Voir la source
-
Performance evaluation of a variable speed DC c...
- Auteurs : EKREN O., CELIK S., NOBLE B., et al.
- Date : 05/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 3
- Formats : PDF
Voir la fiche
-
Application of a lumped model for predicting en...
- Auteurs : NAVARRO-ESBRÍ J., GINESTAR D., BELMAN J. M., et al.
- Date : 04/2010
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 30 - n. 4
Voir la fiche
-
Úspory energie vhodným rízením obehových cerpadel.
- Auteurs : BASTA J.
- Date : 2011
- Langues : Tchèque
- Source : Vytápení Vetrání Instalace - vol. 20 - n. 4
- Formats : PDF
Voir la fiche
-
Optimal environmental performance of water-cool...
- Auteurs : YU F. W., CHAN K. T.
- Date : 2010
- Langues : Anglais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 27 - n. 4
Voir la fiche
-
Utilisation des tensoconvertisseurs de pression...
- Auteurs : GAVRISHCHUK V. I., VASIN A. P., PERVYH M. I., FILIN S. A.
- Date : 1992
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 3
Voir la fiche