Résumé
The refrigeration equipments commonly used in industrial, commercial and residential applications, heat pumps and air conditioning systems are normally operated and controlled by the use of On-Off or PID control. In the last decades the compressor with variable speed is appearing as a good option in terms of energy consumption and electronic expansion valve as well. This paper reports an experimental investigation of a refrigeration system operating with a variable speed compressor and an electronic expansion valve focusing on the reduction of the energy consumption and improvement of the COP. This study worked the use of the adaptive controller hybrid fuzzy (PI fuzzy and PD fuzzy) and using to the inlet of the hybrid-fuzzy control the evaporation temperature calculated with the value of the overall heat transfer coefficient (UA), considered the most relevant parameter of the system. This proportioned the better operation trajectory of the system, where the system operates in the maximum COP regions, improving the performance of the system.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Control and optimization of the refrigeration system based on the most relevant parameter.
- Identifiant de la fiche : 30001662
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
- Voir les traductions : Control y optimización de un sistema de refrigeración aplicando tecnicas fuzzy adaptativas.
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
-
Frequency converters with a field bus: an oppor...
- Auteurs : WURM H. P.
- Date : 17/10/2000
- Langues : Anglais
- Source : Symposium 2000. Cost savings and improved environmental protection by means of more energy efficient refrigeration/air conditioning systems.
Voir la fiche
-
Energy efficiency of small refrigeration system...
- Auteurs : NOVAK L.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
Capacity control in ground source heat pump sys...
- Auteurs : MADANI H., CLAESSON J., LUNDQVIST P.
- Date : 12/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
Voir la fiche
-
Control y optimización de un sistema de refrige...
- Auteurs : BANDARRA FILHO E. P., MENDOZA O. S. H., GARCIA F. E. M.
- Date : 04/2012
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 40 - n. 446
- Formats : PDF
Voir la fiche
-
Compressori a velocità variabile: vantaggi e sf...
- Auteurs : ARSENIO M.
- Date : 2013
- Langues : Italien
- Source : Industria & Formazione - vol. 37 - n. 373
- Formats : PDF
Voir la fiche