Document IIF
Régulation non-synchrome pour les systèmes frigorifiques de supermarchés.
Anti-synchronizing control for supermarket refrigeration systems.
Auteurs : LARSEN L. F. S., THYBO C., WISNIEWSKI R., et al.
Résumé
A supermarket refrigeration system is a hybrid system with switched nonlinear dynamics and discrete-valued input variables such as opening/closing of valves and start/stop of compressors. Practical and simulation studies have shown that the use of distributed hysteresis controllers to operate the valves leads to synchronization, meaning that the opening and closing actions of the valves coincide. Consequently, the compressor periodically has to work hard resulting in low efficiency, inferior control performance and a high wear on the compressor. In this paper the authors propose two control schemes of low complexity for desynchronizing the valve operations while improving performance. Simulation results indicate the potential increase in efficiency and reduction in wear comparing with traditional control schemes.
Documents disponibles
Format PDF
Pages : ICR07-D1-1625
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Anti-synchronizing control for supermarket refrigeration systems.
- Identifiant de la fiche : 2007-2666
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
- Voir les traductions : Sistemas de refrigeración en supermercados: control anti-sincronización.
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Sistemas de refrigeración en supermercados: con...
- Auteurs : LARSEN L. F. S., THYBO C., WISNIEWSKI R., et al.
- Date : 01/2009
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 37 - n. 410
- Formats : PDF
Voir la fiche
-
Ice slurry systems: why have they not taken off?
- Auteurs : RIVET P.
- Date : 09/2008
- Langues : Anglais
- Source : Infofish int. - n. 5
Voir la fiche
-
Supermarktkälte: Saugdruck optimieren in Bestan...
- Auteurs : BERG P., MÜLLER M.
- Date : 06/2012
- Langues : Allemand
- Source : KI Kälte Luft Klimatechnik - vol. 48 - n. 6-7
Voir la fiche
-
Optimal operation of cooling coils for display ...
- Auteurs : HAGLUND STIGNOR C., FAHLÉN P., SUNDÈN B., et al.
- Date : 17/08/2003
- Langues : Anglais
- Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
Voir la fiche
-
Onderhoud aan zuigercompressoren van commerciël...
- Auteurs : DISSEL R. van
- Date : 10/2010
- Langues : Néerlandais
- Source : Koude & Luchtbehandeling - vol. 103
Voir la fiche