Recommandé par l'IIF

Régulation par apprentissage par renforcement pour les cycles frigorifiques à compression de vapeur.

Reinforcement learning control for vapor compression refrigeration cycle.

Numéro : 210034

Auteurs : DING T. L., SUBIANTORO A., NORRIS S.

Résumé

Vapor compression refrigeration cycles (VCRC) control optimization is an effective method to increase its' reliability and energy efficiency. In modern VCRC systems, the introduction of inverter compressors, electronic expansion valves, fan speed, and pump speed control has significantly increased their controllability. These improvements led to the development of many multivariable and predictive control strategies that improved the system's temperature tracking performance and increased the coefficient of performance (COP) by up to 30% compared to conventional on/off and PID controls. However, a VCRC also has high nonlinearities and parameter couplings, making it difficult to apply these modern control laws. This problem incentivizes the application of reinforcement learning (RL) to optimize VCRC control as RL demonstrated an unprecedented ability to optimize complex control problems. This study explores this idea by using RL to train a direct optimal controller for a VCRC. To test the concept, a VCRC simulation model was developed in the MATLAB Simulink environment to train an RL VCRC controller using the MATLAB reinforcement learning toolbox. The controller's goal is to track the desired internal air temperature and a 10˚C superheat setting. The controller used 17 observations containing the VCRC states, tracking errors, operating conditions, and previous actions to determine the optimal compressor speed and expansion valve opening percentage. The VCRC operating conditions were limited to ambient and internal air temperature ranges of 28-32˚C and 16-20˚C, respectively. This study used the twin delayed deep deterministic policy gradient (TD3) RL algorithm to train the controller. The TD3 training hyperparameters such as the noise model and deep neural network parameters were tuned to balance the exploration and exploitation of the solution space. The training converged to a suboptimal solution after completing 6500 episodes in 5 days using an Intel Core i7-8700 CPU 3.2GHz with 32 GB RAM. The developed RL controller was tested using custom ambient and internal air temperature profiles. The controller tracked both the internal air and superheat temperature settings well with low error and fast response time. However, when the ambient temperature fell below 29˚C, the actuators began to fluctuate, indicating that it did not learn a good policy for this region. This study showed that RL could optimize VCRC control, but more research is necessary to improve it.

Documents disponibles

Format PDF

Pages : 10

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Reinforcement learning control for vapor compression refrigeration cycle.
  • Identifiant de la fiche : 30028605
  • Langues : Anglais
  • Sujet : Technologie
  • Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 05/2021
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (184)
Voir le compte rendu de la conférence