Réponse humaine à la ventilation individualisée sans conduit : impact du mouvement d'air, de la température et de la propreté sur les symptômes ophtalmologiques.
Human response to ductless personalized ventilation: impact of air movement, temperature and cleanness on eye symptoms.
Numéro : 807
Auteurs : DALEWSKI M., FILLON M., BIVOLAROVA M., et al.
Résumé
The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation (DV) was studied in relation to peoples’ health, comfort and performance. This paper presents results on the impact of room air temperature, using of DPV and local air filtration on eye blink rate and tear film quality. In a test room with DV and six workstations 30 human subjects were exposed for four hours to each of the following 5 experimental conditions: 23°C and DV only, 23°C and DPV with air filter, 29°C and DV only, 29°C and DPV, and 29°C and DPV with air filter. At warm environment facially applied individually controlled air movement of room air, with or without local filtering, did not have significant impact on eye blink frequency and tear film quality. The local air movement and air cleaning resulted in increased eye blinking frequency and improvement of tear film quality at 23°C.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Human response to ductless personalized ventilation: impact of air movement, temperature and cleanness on eye symptoms.
- Identifiant de la fiche : 30009945
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Ventilation; Température; Déplacement d'air; Nettoyage; Experimentation; Confort thermique
-
Room air stratification in combined chilled cei...
- Auteurs : SCHIAVON S., BAUMAN F., TULLY B., et al.
- Date : 02/2012
- Langues : Anglais
- Source : HVAC&R Research - vol. 18 - n. 1-2
Voir la fiche
-
Human response to ductless personalized ventila...
- Auteurs : DALEWSKI M., BIVOLAROVA M., FILLON M., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Analyse de la performance des systèmes avec app...
- Auteurs : ZHAO H.
- Date : 05/2011
- Langues : Chinois
- Source : HV & AC - vol. 41 - n. 250
- Formats : PDF
Voir la fiche
-
A design procedure for displacement ventilation...
- Auteurs : ZHIVOV A. M., NIELSEN P. V., RISKOWSKI G., et al.
- Date : 11/2000
- Langues : Anglais
- Source : HPAC Engineering - vol. 72 - n. 11
Voir la fiche
-
Theoretical and experimental study of displacem...
- Auteurs : MAKHOUL A., GHALI K., GHADDAR N.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche