Résultats d'essai de système frigorifique de supermarché avec le R-449A et comparaison avec le R-404A.
Prestazioni impiaoto frigorifero di un supermercato, con R-449A in confronto al R-404A.
Auteurs : GERSTEL J.
Type d'article : Article
Résumé
R-404A has been the global industry standard HFC-refrigerant for commercial and industrial refrigeration in both medium and low temp applications. However due to the implementation of EU F Gas regulation 517/ 2014 and the high global warming potential of R-404A (AR4 100 year GWP = 3922), interest is growing to offer low GWP alternatives which match R-404A performance. DuPont has investigated and found a suitable blend which can match or even beat R-404A performance while reducing GWP significantly. Two approaches have been investigated: The first is to use the new blend for retrofitting existing R-404A/ R-507A-systems and second to design new units with it. This is desirable for large supermarket systems and for retrofit of existing R-404A systems in the field which were designed for nonflammable refrigerants. These approaches will be evaluated by thermodynamic cycle analysis, laboratory experiments and numerous supermarket trials. Results presented from these measurements include a field test in Italy, enabling the performance comparison of R-449A with respect to R-404A baseline data, energy consumption and pressure temperature data.
Documents disponibles
Format PDF
Pages : 45-47
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Prestazioni impiaoto frigorifero di un supermercato, con R-449A in confronto al R-404A.
- Identifiant de la fiche : 30017987
- Langues : Italien
- Source : Industria & Formazione - vol. 39 - n. 392
- Date d'édition : 08/2015
Liens
- Voir les traductions : Results from supermarket system trial with R-449A in comparison with R-404A.
Voir d'autres articles du même numéro (3)
Voir la source
Indexation
-
Thèmes :
HFC;
Supermarchés, meubles de vente - Mots-clés : R404A; Supermarché; HFO; GWP; Efficacité énergétique; Frigorigène
-
Simulación energética del comportamiento de nue...
- Auteurs : MOTA BABILONI A., NAVARRO-ESBRÍ J., BARRAGÁN-CERVERA A., et al.
- Date : 03/05/2016
- Langues : Espagnol
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche
-
Mezclas HFC/HFO para sustituir al R404A en refr...
- Auteurs : MOTA BABILONI A., BARRAGÁN-CERVERA A., NAVARRO-ESBRÍ J., et al.
- Date : 03/05/2016
- Langues : Espagnol
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche
-
Ensayos de nuevas alternativas de bajo GWP al R...
- Auteurs : MINOR B., GERSTEL J.
- Date : 09/2013
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - n. 461
- Formats : PDF
Voir la fiche
-
Low and ultra-low GWP refrigerants to replace R...
- Auteurs : SAN ROMÁN M., ACHAICHIA N.
- Date : 03/05/2016
- Langues : Anglais
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche
-
Análisis teórico de sustitutos de bajo PCA en R...
- Auteurs : NAVARRO-ESBRÍ J., MOTA BABILONI A., HARO ORTUNO J., et al.
- Date : 19/06/2018
- Langues : Espagnol
- Source : CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
Voir la fiche