Experimental results with the first laboratory scale variable geometry ejector (VGE) using isobutane (R600a) are presented. Two geometrical factors, the area ratio and the nozzle exit position, can be actively controlled. The control of the area ratio is achieved by a movable spindle installed in the primary nozzle. The influence of the spindle position (SP) and condenser pressure on ejector performance are studied. The results indicate very good ejector performance for a generator and evaporator temperature of 83°C and 9°C, respectively. COP varied between 0.4 and 0.8, depending on operating conditions. The existence of an optimal SP, depending on the back pressure, is identified. A comparison of the benefit of applying the variable geometry design over a fixed geometry configuration is assessed. For example, for a condenser pressure of 3 bar, an 80% increase in the COP was obtained when compared to the performance of a fixed geometry ejector.
Documents disponibles
Format PDF
Pages : 77-85
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental results with a variable geometry ejector using R600a as working fluid.
- Identifiant de la fiche : 30012263
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 46
- Date d'édition : 10/2014
Liens
Voir d'autres articles du même numéro (21)
Voir la source
Indexation
-
CFD study of a variable area ratio ejector usin...
- Auteurs : VARGA S., LEBRE P. M. S., OLIVEIRA A. C.
- Date : 01/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 1
- Formats : PDF
Voir la fiche
-
Applying a variable geometry ejector in a solar...
- Auteurs : VAN NGUYEN V., VARGA S., SOARES J., DVORAK V., OLIVEIRA A. C.
- Date : 05/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 113
- Formats : PDF
Voir la fiche
-
Geometric parameter optimization of ejector-exp...
- Auteurs : SARKAR J.
- Date : 2009
- Langues : Anglais
- Source : Int. J. Energy Res. - vol. 34 - n. 1
Voir la fiche
-
Experimental determination of the optimum perfo...
- Auteurs : YAPICI R., ERSOY H. K., AKTOPRAKOGLU A., et al.
- Date : 11/2008
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 7
- Formats : PDF
Voir la fiche
-
Comparaison des paramètres expérimentaux et cal...
- Auteurs : PETRENKO V. A., VOLOVIK A. S.
- Date : 2006
- Langues : Russe
- Source : Holodil'na Tehnika i Tehnologiâ - n. 6
Voir la fiche