Séparation du refroidissement sensible et latent dans une application résidentielle : modélisation théorique et essais à échelle réelle pendant le Solar Décathlon 2011.
Separate sensible and latent cooling in a residential application: theoretical modeling and full-scale testing during the 2011 Solar Decathlon.
Numéro : pap. 3251
Auteurs : SCHAUS M., HORTON W. T.
Résumé
The benefits of separate sensible and latent cooling (SSLC) have been demonstrated as a viable methodology for substantial reductions in energy consumption required by cooling, while actively controlling the relative humidity of a space. The use of SSLC technologies can result in improvements to indoor air quality, through removal of excess humidity, caused by either outdoor conditions or building envelope composition. The negative effects of high relative humidity indoors can be mitigated, and improved building energy performance can result. This study examines the effectiveness of implementing SSLC technology in residential applications, specifically in high-performance homes, with commercially available equipment. A system, comprised of a central, conventional air handler to remove sensible loading, combined with a high-efficiency, direct expansion dehumidifier for removal of the latent load, was investigated. The modeling of system components was completed by means of a transient model. Validation was completed through the construction, implementation, and testing of a full-scale, high-efficiency home, as a part of the Department of Energy 2011 Solar Decathlon.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Separate sensible and latent cooling in a residential application: theoretical modeling and full-scale testing during the 2011 Solar Decathlon.
- Identifiant de la fiche : 30006813
- Langues : Anglais
- Source : 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Date d'édition : 16/07/2012
Liens
Voir d'autres communications du même compte rendu (42)
Voir le compte rendu de la conférence
Indexation
-
Gas-powered liquid desiccant dehumidifier.
- Auteurs : RIX J., NEVRALA D., CHAUVET L., PROBERT S. D.
- Date : 1993
- Langues : Anglais
- Source : Appl. Energy - vol. 45 - n. 2
Voir la fiche
-
Separate sensible and latent cooling systems: a...
- Auteurs : NAWAZ K., GLUESENKAMP K.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Développement et étude expérimentale sur le rot...
- Auteurs : OKANO H., HIROSE T.
- Date : 10/2001
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 83
Voir la fiche
-
Chilled-water cooling and dehumidifying coils w...
- Auteurs : YIK F. W. H., UNDERWOOD C. P., CHOW W. K.
- Date : 1997
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 18 - n. 1
Voir la fiche
-
Moisture control and cooling ceiling.
- Auteurs : STEIMLE F.
- Date : 09/09/1997
- Langues : Anglais
- Source : International Symposium on Air Conditioning in High Rise Buildings - 1997
- Formats : PDF
Voir la fiche