Serpentins des échangeurs de chaleur : rôle de la filtration dans le maintien de la propreté. Rapport définitif.
The role of filtration in maintaining clean heat exchanger coils. Final report.
Auteurs : LI Y., BRAUN J. E., GROLL E. A.
Type de monographie : Rapport
Résumé
This report was prepared as an account of work sponsored by ARTI under its "HVAC&R Research for the 21st Century Program". The main purpose of the study was to investigate the role of filtration in maintaining clean heat exchanger coils and overall performance. Combinations of 6 different levels of filtration and 4 different coils were tested at 4 different air velocities. The experimental results for pressure drops and heat transfer coefficients were correlated and the correlations were implemented within computer models of prototypical rooftop air conditioners and used to evaluate the impact of fouling on cooling capacity and EER. Extract from the table of contents: experimental equipment and procedures (selection of test coils; filters and equipment; test facility; instrumentation; data acquisition and control system); test results (air-side pressure drops/heat transfer coefficients and fouling factors for wet condition; comparison between dry and wet conditions); indoor-air quality effects; equipment performance effects. This report can be downloaded from: www.arti-21cr.org/research/completed/finalreports.
Détails
- Titre original : The role of filtration in maintaining clean heat exchanger coils. Final report.
- Identifiant de la fiche : 2005-2895
- Langues : Anglais
- Édition : ARTI (Air-Conditioning and Refrigeration Technology Institute) - États-unis/États-unis
- Date d'édition : 06/2004
- Source : Source : ARTI-21CR-611-40050-01; 115 p. (21 x 29.7); fig.; tabl.; ref.; append.
Indexation
-
Thèmes :
Evaporateurs, condenseurs et autres échangeurs thermiques;
Transfert de chaleur;
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité - Mots-clés : Coefficient de transfert de chaleur; Filtre; Température; Recommandation; Recherche; Qualité de l'air; Serpentin; Performance; Modélisation; Filtration; États-Unis; Essai; Équipement; Encrassement; Échangeur de chaleur; Chute de pression
-
Flow-capacity rating and application of suction...
- Auteurs : ARI
- Date : 2001
- Langues : Anglais
Voir la fiche
-
2005 Standard for flow-capacity rating of sucti...
- Auteurs : ARI
- Date : 2005
- Langues : Anglais
Voir la fiche
-
LES CARACTERISTIQUES THERMOHYDRAULIQUES D'UN RE...
- Auteurs : FABJAN L., PETELIN S., GASPERSIC B.
- Date : 1986
- Langues : Français
- Source : Rev. gén. Froid - vol. 76 - n. 7-8
Voir la fiche
-
Investigation on fouling of enhanced tubes used...
- Auteurs : SHEN C., GAO R., WANG X., et al.
- Date : 08/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
Voir la fiche
-
Effects of biofouling on air-side heat transfer...
- Auteurs : PU H., DING G. L., MA X. K., et al.
- Date : 08/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 5
- Formats : PDF
Voir la fiche