Simulation d’un système à écoulement de frigorigène multi-split variable à usage domestique recombiné à des climatiseurs de type split.
Simulation of recombined household multi-split variable refrigerant flow system with split-type air conditioners.
Résumé
In order to effectively utilize the outdoor units and minimize material waste and reinvestment in the replacement of split-type air conditioners by a new household multi-split variable refrigerant flow (VRF) system, a recombined household multi-split VRF system with original split-type air conditioners has been introduced in residential buildings. The equal frequency allocation principle and switching principle for three outdoor-unit operation modes have been determined for the recombined system. A universal model available for both the split-type air conditioner and the recombined household multi-split VRF system has been developed. The model was used for the design of the split-type air conditioners and the recombined system for a typical one-family household in three cities. Then, the cooling season energy performance of the split-type air conditioners and the recombined system were predicted by hourly calculation. According to the results, compared with split-type air conditioners, the recombined system can reduce the start-and-stop energy loss and work at higher compressor efficiency by optimizing the operation mode of outdoor units. The predicted energy saving ratio of the recombined household multi-split VRF system in the cooling season for the typical one-family household is 12.1%, 11.6% and 11.6% in Beijing, Shanghai and Guangzhou, respectively.
Détails
- Titre original : Simulation of recombined household multi-split variable refrigerant flow system with split-type air conditioners.
- Identifiant de la fiche : 30021277
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 117
- Date d'édition : 05/05/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2017.02.003
Liens
Voir d'autres articles du même numéro (17)
Voir la source
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Débit variable; Conditionneur d'air; Simulation; Immeuble d'habitation; Écoulement; Frigorigène
-
Les climatiseurs réversibles, résidentiels et p...
- Date : 11/1992
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - n. 762
Voir la fiche
-
En route for comfort: Biddle gain major CAA con...
- Date : 1994
- Langues : Anglais
- Source : H&V Eng. - vol. 66 - n. 721
Voir la fiche
-
Effect of reduced evaporator airflow on the hig...
- Auteurs : RODRIGUEZ A. G., O'NEAL D., et al.
- Date : 10/1996
- Langues : Anglais
- Source : Energy Build. - vol. 24 - n. 3
Voir la fiche
-
Effect of room modelling and sensor position on...
- Auteurs : RIEDERER P., DEXTER A. L.
- Date : 03/2003
- Langues : Anglais
- Source : Build. Serv. Eng. Res. Technol. - vol. 24 - n. 1
Voir la fiche
-
Colorado-Tower effektiv und preisgünstig klimat...
- Date : 05/12/2003
- Langues : Allemand
- Source : CCI.Print - vol. 37 - n. 14