Simulation et optimisation d'un caloduc en boucle avec un évaporateur de type plat.

Simulation and optimization of loop heat pipe with flat-plate type evaporator.

Auteurs : GAI D. X., LIU Z. C., LIU W.

Résumé

This study is devoted to simulate the system characteristics of high heat-flux LHP with a flat-plate type evaporator and a normal condenser. A unified system model including all components is developed and the node-parameter method is used to simulate the transport performance of LHP system. The simulation for the LHP system is conducted to analyze start-up performance under different heating power and operating characteristic at different heat-flux level and variable heat load. The node parameters are matched between two neighboring modules, and the whole system is well responded with the I/O parameters. The simulation results indicate the changes of pressure, temperature and mass-flux rate with the time at each nodes and the influence of various initial parameters on the LHP performance and with the results, the physical mechanism of transport process is verified and the system structure is optimized for the better understanding in the design of the high-efficiency LHP.

Documents disponibles

Format PDF

Pages : ICR07-B2-510

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Simulation and optimization of loop heat pipe with flat-plate type evaporator.
  • Identifiant de la fiche : 2008-0100
  • Langues : Anglais
  • Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Date d'édition : 21/08/2007

Liens


Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence