Simulation par ordinateur d'un système frigorifique à absorption à ammoniac utilisant des capteurs solaires à tubes sous vide.

Computer simulation of ammonia absorption refrigeration system using evacuated tube solar collectors.

Numéro : pap. n. 3.2

Auteurs : BADRAN A., ATYANI M.

Résumé

Ammonia absorption cycle using an evacuated tube solar collector as the heat source was theoretically investigated. The cycle performance was studied using MATLAB computer software. Optimum generator temperatures which optimize the coefficient of performance at each evaporator, condenser and absorber temperatures were investigated. Evacuated-tube solar collector was found to be suitable to provide the required heat at the proper temperature of the cycle. The obtained results showed a good agreement with those in literature. Evacuated tube solar collectorshowed a good potential in refrigeration system applications. But it was found that evacuated tube solar collector did not reach the optimum generatortemperature under the high condenser and absorber temperatures.

Documents disponibles

Format PDF

Pages : 12 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Computer simulation of ammonia absorption refrigeration system using evacuated tube solar collectors.
  • Identifiant de la fiche : 30006060
  • Langues : Anglais
  • Source : 4th Jordanian IIR International Conference on Refrigeration and Air Conditioning. Proceedings: Amman, Jordan, September 10-12, 2012.
  • Date d'édition : 10/09/2012