Résumé
The absorption refrigeration cycle is important for energy saving which can be driven by low-grade energy. The authors consider the trifluoromethane (HFC-23) + N,N-dimethylformamide (DMF) binary mixture as a promising new working fluid or part of new working fluid for the absorption cycle. Vapor-liquid equilibrium data of the mixture HFC-23 + DMF have been measured in the temperature range from 283.15 to 363.15 K by an equilibrium apparatus in which vapor phase is continuously recirculated. The experimental data are correlated with an Antoine-type equation. The average relative deviation between the experimental data and calculated results is 1.8%, and the results show a good agreement with the experimental data.
Documents disponibles
Format PDF
Pages : 6 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Solubility of refrigerant trifluoromethane in N,N-dimethylformamide in the temperature range from 283.15 to 363.15 K.
- Identifiant de la fiche : 30002954
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Date d'édition : 21/08/2011
Liens
Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence
Indexation
-
Study on a novel absorption refrigeration syste...
- Auteurs : HE Y. J., ZHU Z. W., GAO X., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
The characteristics of a new absorption refrige...
- Auteurs : CHEN G., ZHONG Y.
- Date : 24/09/2002
- Langues : Anglais
- Source : Proceedings of the International Sorption Heat Pump Conference.
Voir la fiche
-
Thermodynamic properties of organic refrigerant...
- Auteurs : DVOSKIN N., JELINEK M., LEVY A., et al.
- Date : 02/08/2005
- Langues : Anglais
- Source : Commercial Refrigeration. Thermophysical Properties and Transfer Processes of Refrigerants. Proceedings of the IIR International Conferences.
- Formats : PDF
Voir la fiche
-
Thermal conductivity of NH3-LiNO3.
- Auteurs : CUENCA Y., VERNET A., VALLÈS M.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Vapour pressure of alkitrate working pairs for ...
- Auteurs : ÁLVAREZ M., BOUROUIS M., SALAVERA D., et al.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche