Solution de conception de la sécurité incendie en développement durable : une étude de cas.
Fire engineering solution for ecological sustainable development (ESD) design: a case study.
Auteurs : POH W.
Type d'article : Article, Étude de cas
Résumé
This paper presents a case study of a four-storey public building that contains a large internal atrium void. The ESD design for the building demands it to be internally "open" to allow free natural airflow, and to have minimum mechanical air-handling system. These are fundamentally in conflict with the Building Code of Australia prescribed requirements, which call for compartmentation and a high-volume smoke exhaust system. In order to resolve the conflicts, a fire engineering solution was developed. The key strategy was to utilise the atrium space as a smoke reservoir and to naturally vent smoke out of the building from the atrium roof. The roofline is raised to form a curved shape to protect the vent openings from adverse wind effects and to create wind suction to further drag smoke out of the building. Analyses of smoke flow and occupant evacuation for the building show that a high level of fire safety is achieved with the design, and that a fire engineering solution can be developed to commensurate with the ESD design.
Documents disponibles
Format PDF
Pages : pp. 38-47 (8 p.)
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Fire engineering solution for ecological sustainable development (ESD) design: a case study.
- Identifiant de la fiche : 2010-1581
- Langues : Anglais
- Source : EcoLibrium - vol. 9 - n. 8
- Date d'édition : 09/2010
Liens
- Liens externes :
Voir d'autres articles du même numéro (2)
Voir la source
Indexation
- Thèmes : Autres équipements de conditionnement d'air
- Mots-clés : Local public; Incendie; Sécurité; Bâtiment commercial; Ventilation; Conception; Australie; Atrium; Étude de cas; Conditionnement d'air
-
Sydney pub's big energy saving and 100% fresh air.
- Auteurs : GOODWIN D.
- Date : 07/2004
- Langues : Anglais
- Source : Celsius - vol. 32 - n. 7
Voir la fiche
-
Grand marché de Vichy : l'air traité diffusé pa...
- Date : 04/2007
- Langues : Français
- Source : Chaud Froid Plomb. - n. 700
Voir la fiche
-
Hybrid earth air duct system for cooling of an ...
- Auteurs : AGGARWAL S. S., KUMAR S., CHAND I.
- Date : 03/2004
- Langues : Anglais
- Source : Archit. Sci. Rev. - vol. 47 - n. 1
Voir la fiche
-
Mit dem RWA (Rauch und Wärmeabzugsanlagen)-Syst...
- Auteurs : BAUMANN C., LOMMATZSCH N., SCHININA M.
- Date : 27/02/2004
- Langues : Allemand
- Source : CCI.Print - vol. 38 - n. 3
Voir la fiche
-
Alternative to the conventional heating and coo...
- Auteurs : KOSIR M., KRAINER A., DOVJAK M., et al.
- Date : 2010
- Langues : Anglais
- Source : Stroj. vestn. - J. mech. Eng. - vol. 56 - n. 9
- Formats : PDF
Voir la fiche