Stratégie d'allocation de puissance pour des unités extérieures à modules multiples dans un système de conditionnement d'air à débit de frigorigène variable.
Capacity allocation strategy for multi-module outdoor units in variable refrigerant flow air conditioning system.
Résumé
Variable refrigerant flow (VRF) air conditioning system has developed into multi-module outdoor units with inverter compressor installed in each module, in which the compressor operating frequencies are undetermined. In this paper, the performance of VRF air conditioning system with two parallel outdoor units is studied, and the capacity allocation strategy for parallel outdoor units is proposed. Firstly, models including compressor, heat exchanger, expansion valve and VRF air conditioning system with multi-module outdoor units were described mathematically. Then, the VRF air conditioning system with two parallel outdoor units operating in a certain frequency range were simulated in nominal cooling condition, in the cases of two identical parallel outdoor units and two different parallel outdoor units. The results indicate that a highest efficiency can be achieved at the frequency ratio region of 0.9~1.0 in the case of identical parallel outdoor units, while the most efficient frequency ratio region is 1.1~1.3 in the case of different parallel outdoor units. Finally, a capacity allocation strategy of compressor speed synchronization for multi-module outdoor units is proposed from the aspect of highest efficiency of VRF air conditioning system.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Capacity allocation strategy for multi-module outdoor units in variable refrigerant flow air conditioning system.
- Identifiant de la fiche : 30015870
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0224
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
-
Simulation numérique de l'écoulement du frigori...
- Auteurs : DENG B., TAO W., LIN L.
- Date : 02/2006
- Langues : Chinois
- Source : HV & AC - vol. 36 - n. 182
- Formats : PDF
Voir la fiche
-
Simulation numérique de l'écoulement du frigori...
- Auteurs : DENG B., TAO W., LIN L.
- Date : 10/2006
- Langues : Chinois
- Source : HV & AC - vol. 36 - n. 190
- Formats : PDF
Voir la fiche
-
Simulation of refrigerant flow boiling in serpe...
- Auteurs : WU H. L., PENG X. F., YE P., et al.
- Date : 03/2007
- Langues : Anglais
- Source : International Journal of Heat and Mass Transfer - vol. 50 - n. 5-6
Voir la fiche
-
Low GWP refrigerants modelling study for a room...
- Auteurs : SHEN B., BHANDARI M., RANE M. V., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Flow characteristics of air-water two phase flo...
- Auteurs : MAHMUD M. S., KAWAZOE A., MUSTAGHFIRIN M. A., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche