Document IIF
Système de purge sans moteur des gaz non absorbables pour les transformateurs de chaleur à absorption.
Non-absorbable gasses motor-less purge system for absorption heat transformers.
Auteurs : EVRON Y., GOMMED K., GROSSMAN G.
Type d'article : Article de la RIF
Résumé
Non-absorbable gasses in absorption heat pumps are well known to significantly hamper their performance. It is hard to prevent the presence of non-absorbable gasses; therefore, regular purging is required. Publications describing earlier work on purge systems for absorption heat transformers (or type II absorption heat pumps) are relatively scarce. The goal of this work has been to design and install a motor-less (no pumping motor added to the system other than that already existing as part of the AHT) purge system that continuously collects and evacuates non-absorbable gasses from our laboratory scale 10 kW LiBr-H2O absorption heat transformer. This system was built, installed and tested. The measurements indicate that the system performs well and successfully removes non-absorbable gasses.
Documents disponibles
Format PDF
Pages : 81-89
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Non-absorbable gasses motor-less purge system for absorption heat transformers.
- Identifiant de la fiche : 30027841
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 120
- Date d'édition : 12/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.09.001
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (42)
Voir la source
Indexation
-
Analysis of the process characteristics of an a...
- Auteurs : GENSSLE A., STEPHAN K.
- Date : 01/2000
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 39 - n. 1
Voir la fiche
-
Design and experimental performance evaluation ...
- Auteurs : ABRAHAMSSON K., GIDNER A., JERNQVIST A.
- Date : 04/1995
- Langues : Anglais
- Source : Heat Recov. Syst. CHP - vol. 15 - n. 3
Voir la fiche
-
L'utilisation des ressources thermiques résidue...
- Auteurs : PORNEALA S.
- Date : 06/1997
- Langues : Roumain
- Source : ECO-CLIMA - n. 2
Voir la fiche
-
Absorptionswärmetransformator und Absorptionswä...
- Auteurs : CUDOK F., KONONENKO N., ZIEGLER F.
- Date : 11/2014
- Langues : Allemand
- Source : KI Kälte Luft Klimatechnik - n. 11
Voir la fiche
-
Static simulation of multistage absorption heat...
- Auteurs : TANO H., SAITO K., INOUE N.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche