Systèmes frigorifiques à CO2.
CO2 køleanlaeg.
Auteurs : PACHAI A. C.
Type d'article : Article
Résumé
CO2 was used for many years before the Second World War, but after this, CO2 disappeared rapidly and was replaced by synthetic refrigerants and NH3. Over the last three years, three CO2 cascade supermarket systems have been installed in the Copenhagen area. The experience has been good. CO2 is used in the entire supermarket and only a very small charge has been used on the high-temperature side of the cascade system. Also, industrial systems have been introduced onto the market. On fishing vessels, the new refrigeration system makes it possible to obtain higher prices for the fish frozen in the plate freezers after the introduction of hot-gas defrost of the freezer. The fish on the top are not damaged during the whole process as normally seen. Also, safety is not considered to be an issue. All precautions are taken to avoid problems. The only problems seen in a CO2 system are related to the presence of large amounts of water. The paper also discusses a major power black-out in 2003 in the southern part of Sweden and the eastern part of Denmark. Only minor problems where reported.
Documents disponibles
Format PDF
Pages : 20-23
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : CO2 køleanlaeg.
- Identifiant de la fiche : 2006-1616
- Langues : Norvégien
- Source : Kulde Skand. - vol. 19 - n. 2
- Date d'édition : 2004
Liens
Voir d'autres articles du même numéro (1)
Voir la source
Indexation
- Thèmes : CO2
- Mots-clés : Système frigorifique; Installation frigorifique; Frigorigène; CO2
-
Erfaringer og status for transkritiske CO2-anlaeg.
- Auteurs : POULSEN C. S.
- Date : 2004
- Langues : Norvégien
- Source : Kulde Skand. - vol. 19 - n. 2
- Formats : PDF
Voir la fiche
-
CO2 als koudemiddel: utopie, compromis of een r...
- Date : 10/2001
- Langues : Néerlandais
- Source : Koude & Luchtbehandeling - vol. 94 - n. 10
Voir la fiche
-
Aldi hat Deutschlands erste CO2-Komplett-Kältea...
- Auteurs : STAHL M.
- Date : 06/10/2006
- Langues : Allemand
- Source : CCI.Print - vol. 40 - n. 11
- Formats : PDF
Voir la fiche
-
Neue Studie zur Ökoeffizienz von Supermarktkält...
- Date : 12/2010
- Langues : Allemand
- Source : Kälte + Klimatechnik (Die) - vol. 63 - n. 12
Voir la fiche
-
Heat exchangers in carbon dioxide cascade syste...
- Auteurs : STENHEDE C.
- Date : 05/2007
- Langues : Anglais
- Source : IRHACE J. - vol. 19 - n. 3
Voir la fiche