Systèmes hybrides de chauffage, ventilation et conditionnement d'air à déshumidification chimique pour les applications dans les grandes surfaces.
Hybrid HVAC systems with chemical dehumidification for supermarket applications.
Auteurs : CAPOZZOLI A., MAZZEI P., MINICHIELLO F., et al.
Type d'article : Article
Résumé
HVAC systems in supermarkets must assure both thermal comfort for occupants and suitable climatic conditions for refrigerated cases, which operate better with low ambient relative humidity (40-45%). Since open display cases substantially reduce sensible load and moderately reduce latent load, ambient sensible/total heat load ratio is less than usual. Thus, if dehumidification is carried out with a traditional cooling coil, over-sizing of the coil and re-heating of the treated air are necessary, with energy and economic waste. To offset these disadvantages, hybrid HVAC systems with chemical dehumidification may be employed. In this paper a case study is presented in which a traditional HVAC system is compared to hybrid systems with chemical dehumidification. Dynamic simulation codes (DOE and DesiCalcT) and test reference year data, opportunely elaborated, have been used. Annual operating costs have been estimated and large savings have been obtained with hybrid systems. Considerable reduction of electric energy demand as well as better control of thermal-hygrometric conditions were noted. A simple payback of about 1 year has been obtained. Finally, a virtual retrofitting operation on 30% of the existing HVAC systems in Italian supermarkets has shown significant operating cost savings. [Reprinted with permission from Elsevier. Copyright, 2005].
Détails
- Titre original : Hybrid HVAC systems with chemical dehumidification for supermarket applications.
- Identifiant de la fiche : 2006-2614
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 26 - n. 8-9
- Date d'édition : 06/2006
Liens
Voir d'autres articles du même numéro (8)
Voir la source
Indexation
-
DUCTLESS, MULTIZONE SPLIT SYSTEM PROVIDES NEW D...
- Auteurs : ESPARZA R.
- Date : 07/1987
- Langues : Anglais
- Source : Heat. Pip. Air Cond. - vol. 59 - n. 7
Voir la fiche
-
FIELD MONITORING OF THE WINTER PERFORMANCE OF A...
- Auteurs : TSONGAS G. A., WRIDGE R. S.
- Date : 1989
- Langues : Anglais
Voir la fiche
-
HUMIDIFICATEURS ET DESHUMIDIFICATEURS EN CONDIT...
- Date : 27/05/1991
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - vol. 46 - n. 730
Voir la fiche
-
Experimental performance analysis and modelling...
- Auteurs : PIETRUSCHKA D., EICKER U., HUBER M., et al.
- Date : 01/2006
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 29 - n. 1
- Formats : PDF
Voir la fiche
-
Experimental investigation on the local air age...
- Auteurs : WANG F., LI Y., LIU X., et al.
- Date : 20/05/2009
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
Voir la fiche