SYSTEMES PASSIFS POUR LE CHAUFFAGE ET LE REFROIDISSEMENT SOLAIRES. I. EXPERIENCES SUR LES SYSTEMES PASSIFS RELIES A UNE CHAMBRE D'ESSAI.

[In Japanese. / En japonais.]

Auteurs : OKA T.

Type d'article : Article

Résumé

LA CHAMBRE D'ESSAI ETAIT UNE CAISSE EN BETON (4 X 4 X 2 M) DE 12 CM D'EPAISSEUR, ENFERMEE DANS UNE CHAMBRE DE GARDE, SAUF LA FACADE ORIENTEE AU SUD, AFIN DE REDUIRE L'INFLUENCE DE LA TEMPERATURE DE L'AIR AMBIANT ET DU RAYONNEMENT SOLAIRE. LA FACADE EXPOSEE AU SUD ETAIT RECOUVERTE D'UNE SEULE VITRE ET DE SYSTEMES PASSIFS TELS QU'UNE PAROI DE TROMBE ET UN RIDEAU D'EAU. LES EXPERIENCES ONT ETE EFFECTUEES EN HIVER ET LES RESULTATS SE RAPPORTANT A LA TEMPERATURE DE L'AIR DE LA CHAMBRE, A LA TEMPERATURE DE L'AIR AMBIANT ET A L'ENERGIE SOLAIRE INCIDENTE A TRAVERS LA VITRE ONT ETE RECUEILLIS POUR EVALUER LES SYSTEMES PASSIFS. LA PAROI DE TROMBE TENDAIT A MAINTENIR CONSTANTE LA TEMPERATURE DE L'AIR A UNE CAPACITE CALORIFIQUE ELEVEE. LA TEMPERATURE DES RIDEAUX D'EAU AUGMENTAIT EN FONCTION DE L'ENERGIE SOLAIRE INCIDENTE ET VARIAIT EN FONCTION DU DECALAGE DANS LE TEMPS DE LA TEMPERATURE DE L'AIR DE LA CHAMBRE.

Détails

  • Titre original : [In Japanese. / En japonais.]
  • Identifiant de la fiche : 1983-2313
  • Langues : Japonais
  • Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 21
  • Date d'édition : 1983
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres articles du même numéro (2)
Voir la source