Test du ventilateur bloqué.

Blocked fan test.

Auteurs : TOMELL P.

Résumé

An internal pressure relief valve (IPRV) is used to limit the maximum system pressures by venting the discharge gas into the suction side of the compressor. The IPRV works with the overload protector to keep the system from unsafe operation. Air conditioning units with an IPRV were blocked fan tested. Systems that operate in high ambient conditions can open the IPRV and cause nuisance shutdowns. Recently designed systems with minimized coil size has required the reexamination of IPRV selection. A brief review of the conflicting requirements and resolution is proposed.

Détails

  • Titre original : Blocked fan test.
  • Identifiant de la fiche : 1999-3534
  • Langues : Anglais
  • Source : Proceedings of the 1998 International Compressor Engineering Conference at Purdue (ICECP 1998).
  • Date d'édition : 14/07/1998
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (57)
Voir le compte rendu de la conférence