Tests basés sur la charge pour caractériser les performances des équipements de conditionnement d’air et de pompage de chaleur.
Load-based testing to characterize the performance of air conditioning and heat pumping equipment.
Numéro : pap. 2709
Auteurs : PATIL A, HJORTLAND A., CHENG L., et al.
Résumé
This paper presents a new load-based testing methodology for testing packaged and split air conditioning and heat pumping equipment in a realistic manner that captures interactions between the equipment’s controls and the building. Although this is particularly appropriate for variable-speed equipment, the methodology can also be applied for testing staged equipment. This load-based testing methodology has been developed in collaboration with the Canadian Standards Association (CSA) which aims to develop a new standard that can be used to better predict the seasonal performance of variable-speed units as compared to traditional steady-state test methodologies. The load-based methodology replicates actual building dynamics in psychrometric test chambers by continually updating the room temperature and humidity based on a simple virtual building load model. The paper presents the virtual building load model, discusses some convergence criteria needed to determine when the tests have converged since these tests operate differently as compared to traditional steady-state tests, and provides some example test results for both variable-speed and staged equipment.
Documents disponibles
Format PDF
Pages : 12
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Load-based testing to characterize the performance of air conditioning and heat pumping equipment.
- Identifiant de la fiche : 30024720
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence
Indexation
-
Component-based, gray-box modeling of ductless ...
- Auteurs : CHEUNG H., BRAUN J. E.
- Date : 02/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 38
- Formats : PDF
Voir la fiche
-
Control characteristics of residential air-cond...
- Auteurs : TODATE T., ARIGA S., NISHIGUCHI T., YAMAGUCHI S.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Recherche sur un test de chauffage instable app...
- Auteurs : SHI M., ZHONG Y., ZHANG X.
- Date : 12/2013
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 34 - n. 154
- Formats : PDF
Voir la fiche
-
Experimental analyses of different control stra...
- Auteurs : BARTA R. B., ZIVIANI D., GROLL E. A.
- Date : 04/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 112
- Formats : PDF
Voir la fiche
-
Influence des paramètres environnementaux et ca...
- Auteurs : CHILENKO V. I., PIMKOV A. L., VERCHININ V. S., et al.
- Date : 2000
- Langues : Russe
- Source : Kholodilnaya Tekhnika - n. 11
Voir la fiche