Résumé
This paper focuses on the transient performance of the R290 and R410A heat pumps (HPs) during startup process at low-temperature environment. Capacity, power, pressure and temperature were measured and compared during the cold startup processes of the R290 and R410A HPs. The results show that capacity of R410A HP reached 80% at about 9 min and the R290 did not rise to 80% at 18 min, when ambient temperature was 2℃. The variations of the thermal parameters illustrates that the migration of refrigerant can be the key factor that resulted in the worsen transient performance of R290 HP. The lower discharge temperature and smaller charge amount of R290 result in the refrigerant enriching in compressor and the insufficient liquid at electronic expansion valve (EEV) inlet. Additionally, two control methods were explored to improve the transient performance of R290 HP. Results show that the high compressor frequency improved the capacity to a certain extent while the control of the distribution of refrigerant before startup resulted in the 'oil blockage' of expansion device.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Transient heating performance analysis of R290 and R410A heat pumps during startup process.
- Identifiant de la fiche : 30031383
- Langues : Anglais
- Sujet : Technologie, Alternatives aux HFC
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0193
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
Load-based testing to characterize the performa...
- Auteurs : PATIL A, HJORTLAND A., CHENG L., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Improving performance of an existing heat pump:...
- Auteurs : BAHEL V., LANZER S., SHIVASHANKAR S., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
A simplified model for assessing improvement po...
- Auteurs : ASLOUNE H., RIVIÈRE P.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Fast predicting method for maximum APF of heat ...
- Auteurs : REN T., SHEN J., WU G., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Développement d'une thermofrigopompe au propane.
- Auteurs : GHOUBALI R.
- Date : 10/10/2013
- Langues : Français
- Source : Pôle Cristal Symposium - 6th edition.
- Formats : PDF