Document IIF
The auditing and analysis of commercial building energy conservation design in Taiwan.
Auteurs : YANG K. H., WU S. C., CHIANG Y. S., CHEN W. C., LIAO W. F.
Résumé
Field measurement indicated that HVAC system consumes over 45 % energy of a typical commercial building in this area, and is the main cause for power shortages during the summer. A research program was initiated by the National Science Council to conduct energy auditing on commercial buildings where energy use data were collected and visualized for diagnostics through computer. Chiller plant power consumption recorded showed that around 0.7 kW/RT performance was obtained for a typical 200 USRT centrifugal chiller operating under local weather conditions, which is comparable to the performance under ARI 550 test conditions. Furthermore, ASHRAE standerd procedure to simulate centrifugal chillers was applied which successfully correlated refrigeration capacity, power consumption, chiller supply water and cooling water temperatures.- This experimental model enabled performance evaluation under full load and partial load conditions and deviations were controlled within 5 %.
VAV ( Variable Air Volume ) system was also studied followed with fullscale experiment, resulting in energy savings of over 20 % under partial load conditions. These successful results constructed the important database of the local building energy code, and is discussed in detail in this paper.
Documents disponibles
Format PDF
Pages : p 328-333
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : The auditing and analysis of commercial building energy conservation design in Taiwan.
- Identifiant de la fiche : 30033779
- Langues : Anglais
- Sujet : Chiffres, économie
- Source : International Symposium on Air Conditioning in High Rise Buildings - 1997
- Date d'édition : 09/1997
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (94)
Voir le compte rendu de la conférence
Indexation
-
Análisis fluido-dinámico de una vitrina autoser...
- Auteurs : SOTO R., RODRÍGUEZ A., ARAIZ M., ELOSUA I. , ASTRAIN D.
- Date : 26/06/2024
- Langues : Espagnol
- Source : 12th CYTEF Congress - Ibero-American Congress of Refrigeration Science and Technology.
- Formats : PDF
Voir la fiche
-
Energy efficiency and flexible performance by i...
- Auteurs : PAJDZIK L., RICH T., BICEAN I., KLYSZEJKO A., SHAXTED J., RENSHAW A.
- Date : 07/04/2025
- Langues : Anglais
- Source : Cryogenics 2025. Proceedings of the 18th IIR International Conference on Cryogenics, Prague, Czech Republic, 7-11 April 2025.
- Formats : PDF
Voir la fiche
-
Compact modeling of compressed air distribution...
- Auteurs : YAZAWA K., LAORANGE G., VOORHIS M., SHAKOURI A.
- Date : 17/07/2024
- Langues : Anglais
- Source : 2024 Purdue Conferences. 20th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
THE NUMERICAL SOLUTION OF CRYOGENIC REGENERATOR...
- Auteurs : YUAN X.
- Date : 24/08/1987
- Langues : Anglais
- Source : Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Airflow based model to estimate commercial buil...
- Auteurs : GUNNSTEINSSON S., KAHN R., GEVELBER M.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 4th International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche