Transfert d'humidité dans les réfrigérateurs domestiques.

Moisture transport in domestic refrigerators.

Auteurs : INAN C., EGRICAN N., BULLARD C., et al.

Résumé

Assessments of the moisture loading of a refrigerator cabinet during closed door and open door conditions are considered. During closed door conditions, moisture transport is related to differences in water vapour pressure between the cabinet and its surroundings. Open door moisture transport relations are developed from experimental open door convection results. Finally, the energy implication of moisture removal by defrost heating is considered.

Détails

  • Titre original : Moisture transport in domestic refrigerators.
  • Identifiant de la fiche : 2003-1301
  • Langues : Anglais
  • Source : ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
  • Date d'édition : 12/01/2002
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (73)
Voir le compte rendu de la conférence