Experimental shell-side heat transfer and pressure drop in gas flow for spiral-wound LNG heat exchanger.

Author(s) : NEERAAS B. O., FREDHEIM A. O., AUNAN B.

Type of article: Article

Summary

A test plant has been constructed for measurements of local heat-transfer coefficients and frictional pressure drops on the shell side of spiral-wound LNG heat exchangers. Measurements have been performed with gas flow, liquid film flow and two-phase shear flow. This paper focuses on the measurements and the results from the gas flow measurements. 221 gas flow heat-transfer measurements and 80 gas flow frictional pressure drop measurements have been performed at a Re-number range of 5000-170 000 with nitrogen, methane, ethane and methane/ethane mixture as test fluids.

Details

  • Original title: Experimental shell-side heat transfer and pressure drop in gas flow for spiral-wound LNG heat exchanger.
  • Record ID : 2004-1539
  • Languages: English
  • Source: International Journal of Heat and Mass Transfer - vol. 47 - n. 2
  • Publication date: 2004/01

Links


See other articles in this issue (3)
See the source