Transfert de chaleur et chute de pression lors de la condensation du frigorigène R1234yf doté d'un faible potentiel de réchauffement planétaire.

Heat transfer and pressure drop during condensation of the low GWP refrigerant R1234yf.

Auteurs : DEL COL D., TORRESIN D., CAVALLINI A.

Type d'article : Article, Article de la RIF

Résumé

This paper reports local heat transfer coefficients measured during condensation of R1234yf within a single circular 0.96 mm diameter minichannel and compares them to the ones of R134a. This experimental work is carried out in a unique test apparatus which allows to determine the local heat flux extracted from the condensing fluid from the temperature profile of the coolant. For this purpose, the temperatures of the coolant and of the wall are measured along the test section. The saturation temperature is determined from the saturation pressure which is measured at inlet and outlet of the test channel. Condensation tests are carried out at mass fluxes ranging between 200 and 1000 kg/m2.s and the heat transfer coefficients result to be lower as compared to the ones of R134a. Since the saturation temperature drop directly affects the heat transfer rate, the pressure drop during adiabatic two-phase flow of R1234yf is also measured and compared to R134a.

Documents disponibles

Format PDF

Pages : pp. 1307-1318

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Heat transfer and pressure drop during condensation of the low GWP refrigerant R1234yf.
  • Identifiant de la fiche : 2010-1085
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 7
  • Date d'édition : 11/2010