Transfert de chaleur lors de l'ébullition convective périodique du R134a et caractéristiques bullaires associées dans un conduit annulaire étroit, en raison de l'oscillation du débit.

Time periodic flow boiling heat transfer of R134a and associated bubble characteristics in a narrow annular duct due to flow rate oscillation.

Auteurs : CHEN C. A., CHANG W. R., LIN T. F.

Type d'article : Article

Résumé

An experiment is conducted to investigate the effects of the imposed time periodic refrigerant flow rate oscillation in the form of nearly a triangular wave on refrigerant R134a flow boiling heat transfer and associated bubble characteristics in a horizontal narrow annular duct with the duct gap fixed at 2.0 mm. The results indicate that when the imposed heat flux is close to that for the onset of stable flow boiling, intermittent flow boiling appears in which nucleate boiling on the heated surface does not exist in an entire periodic cycle. At somewhat higher heat flux persistent boiling prevails. Besides, the refrigerant flow rate oscillation only slightly affects the time-average boiling curves and heat transfer coefficients. Moreover, the heated wall temperature, bubble departure diameter and frequency, and active nucleation site density are found to oscillate periodically in time as well and at the same frequency as the imposed mass flux oscillation. Furthermore, in the persistent boiling the resulting heated wall temperature oscillation is stronger for a longer period and a larger amplitude of the mass flux oscillation. And for a larger amplitude of the mass flux oscillation, stronger temporal oscillations in the bubble characteristics are noted. The effects of the mass flux oscillation on the size of the departing bubble and active nucleation site density dominate over the bubble departure frequency, causing the heated wall temperature to decrease and heat transfer coefficient to increase at reducing mass flux in the flow boiling, opposing to that in the single-phase flow. But they are only mildly affected by the period of the mass flux oscillation. However, a short time lag in the wall temperature oscillation is also noted. Finally, a flow regime map is provided to delineate the boundaries separating different boiling regimes for the R134a flow boiling in the annular duct. [Reprinted with permission from Elsevier. Copyright, 2010].

Détails

  • Titre original : Time periodic flow boiling heat transfer of R134a and associated bubble characteristics in a narrow annular duct due to flow rate oscillation.
  • Identifiant de la fiche : 2010-1787
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 53 - n. 19-20
  • Date d'édition : 09/2010
  • DOI : http://dx.doi.org/10.1016/j.ijheatmasstransfer.2010.02.038

Liens


Voir d'autres articles du même numéro (3)
Voir la source