Résumé
A laboratory test stand for magnetocaloric effect investigations has been developed. The test stand is compact and easily reconfigurable. Gadolinium in the form of particles is used as a refrigerant. The material is magnetized/demagnetized due to the reciprocating motion of a magnetic bed. A Halbach array of permanent magnets is employed as a magnetic field source. It generates a magnetic field of about 1 T. In order to decrease the distance along which the magnetic bed has to move, a magnetic shield was used which limits the range of external magnetic field influence. The effectiveness of the shielding and the decrease in magnetic field intensity were shown in the form of magnetic field distribution maps. The paper presents first experimental results which are measured as the temperature difference between the two outermost reservoirs. The achieved results are promising – the temperature span between the heat exchangers amounts to about 2°C.
Documents disponibles
Format PDF
Pages : 72-77
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A test stand to study the possibility of using magnetocaloric materials for refrigerators.
- Identifiant de la fiche : 30009882
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 37 - n. 1
- Date d'édition : 01/2014
Liens
Voir d'autres articles du même numéro (37)
Voir la source
Indexation
- Thèmes : Froid calorique (froid magnétocalorique, électrocalorique, élastocalorique et barocalorique)
- Mots-clés : Banc d'essai; Réfrigerateur magnétique; Froid magnétocalorique; Conception; Propriété magnétique; Matériau; Magnétisme; Gadolinium; Experimentation; Effet magnétocalorique; Champ magnétique
-
A test stand to study the possibility of using ...
- Auteurs : CZERNUSZEWICZ A., KALETA J., KRÓLEWICZ M., et al.
- Date : 17/09/2012
- Langues : Anglais
- Source : 5th International Conference on Magnetic Refrigeration at Room Temperature (Thermag V). Proceedings: Grenoble, France, September 17-20, 2012.
- Formats : PDF
Voir la fiche
-
Corrosion tests of gadolinium in various heat c...
- Auteurs : ZAMNI L., MAUDNI EL ALAMI S. el, BALLI M., et al.
- Date : 17/09/2012
- Langues : Anglais
- Source : 5th International Conference on Magnetic Refrigeration at Room Temperature (Thermag V). Proceedings: Grenoble, France, September 17-20, 2012.
- Formats : PDF
Voir la fiche
-
Magnetic cooling device working on cold rolled ...
- Auteurs : TASKAEV S., BUCHELNIKOV V., SKOKOV K., et al.
- Date : 17/09/2012
- Langues : Anglais
- Source : 5th International Conference on Magnetic Refrigeration at Room Temperature (Thermag V). Proceedings: Grenoble, France, September 17-20, 2012.
- Formats : PDF
Voir la fiche
-
Magnetocaloric bench: analytical model for gado...
- Auteurs : PLAIT A., GIURGEA S., ESPANET C., et al.
- Date : 11/09/2016
- Langues : Anglais
- Source : 7th International Conference on Magnetic Refrigeration at Room Temperature (Thermag VII). Proceedings: Turin, Italy, September 11-14, 2016.
- Formats : PDF
Voir la fiche
-
Experimental and modeling results of a parallel...
- Auteurs : TURA A., NIELSEN K. K., ROWE A.
- Date : 09/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 6
- Formats : PDF