The absorption heat exchanger (AHE) is designed to decrease the temperature of outlet primary water. A two-stage vertical absorption heat exchanger for district heating system is designed and tested in this research. The system consists of two stages absorption heat pump with different vapor pressure in generator and evaporator, while the two stages are only connected with primary and secondary water. The system is designed to a vertical structure in order to reduce the covered area, which consists of condenser, generator, evaporator and absorber from top to bottom. A simulation model is put up and verified to predict the performance of the system. The performance of this system with 6000 kW heating capacity is tested in Taiyuan with the load rate ranges from 4.7% to 50.0%. The outlet water temperature of primary network is below 20 °C in the past heating seasons, which is 15–25 K lower than inlet water temperature of secondary network. The tested temperature efficiency is 1.250–1.420, while the tested temperature efficiency of single-stage system is 1.140–1.200. The two-stage vertical AHE system has higher temperature efficiency and better performance compared with traditional AHE according to field test.
Documents disponibles
Format PDF
Pages : 19-31
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A two-stage vertical absorption heat exchanger for district heating system.
- Identifiant de la fiche : 30027442
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 114
- Date d'édition : 06/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.02.002
Liens
Voir d'autres articles du même numéro (20)
Voir la source
-
MODEL OF A VAPORIZER FOR REFRIGERATING ABSORPTI...
- Auteurs : GHEORGHIU C.
- Date : 1981
- Langues : Anglais
- Source : Bul. Univ. Galati - vol. 4 - n. 4
Voir la fiche
-
Évaporateurs compacts pour les systèmes à sorpt...
- Auteurs : GIRAUD F., TREMEAC B., VALLON P., et al.
- Date : 03/2017
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - n.1162
Voir la fiche
-
Rozwój racjonalnej energetyki z wykorzystaniem ...
- Auteurs : KOLOLA R., KLUGMANN-RADZIEMSKA E., LEWANDOWSKI W.
- Date : 06/2010
- Langues : Polonais
- Source : Chlodnictwo - vol. 45 - n. 6
Voir la fiche
-
Development and demonstration of a microscale a...
- Auteurs : KEINATH C. M., GARIMELLA S.
- Date : 04/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 88
- Formats : PDF
Voir la fiche
-
Numeryczna analiza mozliwosci zwiekszenia efekt...
- Auteurs : MUSZYNSKI T., MELLER M.
- Date : 05/2016
- Langues : Polonais
- Source : Chlodnictwo - vol. 51 - n. 5
Voir la fiche