Un étude de l'amélioration de la performance d'un système de ventilation à récupération de chaleur.
A study on performance improvement for heat recovery ventilation system.
Numéro : pap. n. 305
Auteurs : CHUNG M. H., OH B. K., BAE S. H.
Résumé
The supply and use of exhaust heat recovery ventilation equipment as effective energy saving equipment has been increasing steadily. Heat recovery ventilation equipment can be installed at ceiling of balcony or emergency space. However, in case of fire, because emergency space has to remain as empty space by law, ventilation systems can’t be installed there. Therefore the need to properly provide space for ventilation system is highlighted. In this study, in order to install heat recovery ventilation systems in light weight wall, thickness of heat exchanger was assembled below 140 mm. The efficiency of heat recovery was analyzed through performance experiment in the case of cooling and heating mode. Heat recovery efficiency increases when the surface area is increased by using closer channel spacing in the heat exchanger or by increasing the size of the heat exchanger. Decreasing the channel spacing was found to be more efficient than increasing the size of the heat exchanger to obtain the same surface area.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A study on performance improvement for heat recovery ventilation system.
- Identifiant de la fiche : 30008895
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Ventilation; Conception; Récuperation de chaleur; Performance; Échangeur de chaleur
-
Scambiatore di calore a tre fluidi con pre-umid...
- Auteurs : CAPELLI D'ORAZIO M., CIANFRINI C., CORCIONE M.
- Date : 03/1998
- Langues : Italien
- Source : Cond. Aria - vol. 42 - n. 3
Voir la fiche
-
Energy recovery possibilities in natural ventil...
- Auteurs : SKARET E., BLOM P., BRUNSELL J. T.
- Date : 23/09/1997
- Langues : Anglais
- Source : Ventilation and cooling. Proceedings of the 18th AIVC Conference.
Voir la fiche
-
Saving energy through simple HVAC heat recovery.
- Auteurs : DWYER T.
- Date : 02/2013
- Langues : Anglais
- Source : CIBSE Journal - vol. 5 - n. 2
Voir la fiche
-
ECHANGEUR DE CHALEUR UTILISE DANS LES SYSTEMES ...
- Auteurs : DANIEL H.
- Date : 08/1991
- Langues : Allemand
- Source : Heiz. Lüft.-Klima Haustech. - vol. 42 - n. 8
Voir la fiche
-
Study of coupled energy saving systems sensitiv...
- Auteurs : SERRES L., TROMBE A., et al.
- Date : 03/1997
- Langues : Anglais
- Source : Build. Environ. - vol. 32 - n. 2
Voir la fiche