Document IIF
Un modèle explicite simplifié pour la détermination de la performance d'un serpentin de refroidissement [d'eau glacée].
A simplified explicit model for determining the performance of a chilled water cooling coil.
Auteurs : LEE C. K.
Type d'article : Article, Article de la RIF
Résumé
A simplified explicit model for the chilled water cooling coil was presented which could determine the performance of even a partially-wet coil without any need for iterative calculations. A quadratic correlation was derived for evaluating the dry portion of a partially-wet coil from the inlet chilled water temperature based on performance data generated from a validated numerical model for a sample coil over a range of operating conditions. By applying the present explicit model to simulate the performance of the sample coil, it was found that the errors in the calculated coil total capacities did not exceed 2.2% when compared with those based on the numerical model. The percentage errors in the simulated coil latent capacities varied widely from 100% for a just-slightly-wet coil down to 0.26% for a fully-wet coil. Nevertheless, the present model was considered an efficient and yet accurate approach for determining the performance of a chilled water cooling coil.
Documents disponibles
Format PDF
Pages : 167-175
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A simplified explicit model for determining the performance of a chilled water cooling coil.
- Identifiant de la fiche : 30011676
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 43
- Date d'édition : 07/2014
Liens
Voir d'autres articles du même numéro (17)
Voir la source
Indexation
-
Degrading chilled water plant delta-T: causes a...
- Auteurs : TAYLOR S. T.
- Date : 12/01/2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
Voir la fiche
-
Influence of coil geometrical parameters on the...
- Auteurs : MOUSAVI AJAROSTAGHI S. S., PONCET S., SEDIGHI K., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Chilled water system forensics.
- Auteurs : LUTHER K. R.
- Date : 12/01/2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
Voir la fiche
-
How to raise chilled water temperature differen...
- Auteurs : FIORINO D. P.
- Date : 12/01/2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
Voir la fiche
-
Comparison of methods of modelling the air-side...
- Auteurs : MIRTH D. R., RAMADHYANI S.
- Date : 1993
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche