Un refroidisseur à tube à pulsation d'une puissance de 1 W à 4,2 K.

A pulse-tube cooler capable of 1 W at 4.2 K.

Auteurs : QIU L. M., JIANG N., GIEBELER F., et al.

Résumé

The cold end heat exchanger in a cryocooler is of highest importance for the efficient heat transfer from the applied load to the working fluid. The cooling performance of a 4 K pulse tube cooler was greatly improved by the modification of the cold end heat exchanger. With no heat loads on the first stage, cooling capacities of 760 and 900 mW at 4.2 K were obtained with compressor input powers of 4.8 and 6.0 kW, respectively. The COPs at 4.2 K were correspondingly improved, which are comparable to those of 4 K G-M cryocoolers. A cooling capacity of 960 mW at 4.2 K was obtained with 5 W heat load on the first stage.

Détails

  • Titre original : A pulse-tube cooler capable of 1 W at 4.2 K.
  • Identifiant de la fiche : 2006-1035
  • Langues : Anglais
  • Source : Cryogenics and refrigeration. Proceedings of ICCR 2003.
  • Date d'édition : 22/04/2003

Liens


Voir d'autres communications du même compte rendu (166)
Voir le compte rendu de la conférence