
Une approche modulaire à l'étude de la performance d'une pompe à chaleur biétagée en application séchage.
A modular approach to study the performance of a two-stage heat pump system for drying.
Auteurs : CHUA K. J., CHOU S. K.
Type d'article : Article
Résumé
The performance of a two-stage evaporator heat pump drying system with HCFC-22 as the working refrigerant was experimentally studied. The system employed low- and high-pressure internal evaporators for cooling and dehumidification of the drying air. On the condenser side, two subcoolers were used for additional sensible heating. The system further incorporated a passive evaporator-economiser for precooling of the air before the evaporators and preheating before the condenser. The system performance was evaluated in terms of the amount of heat recovered at the evaporators, the system COP and specific moisture extraction rate. It was demonstrated in this paper that more heat, up to 35% more, could be recovered via the two-stage evaporator system in comparison to a single evaporator system. By varying the pressure level of the high-pressure evaporator, greater amount of heat recovered could be realised when the ratio of latent to total load at the two-stage evaporator was improved.
Détails
- Titre original : A modular approach to study the performance of a two-stage heat pump system for drying.
- Identifiant de la fiche : 2005-2826
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 25 - n. 8-9
- Date d'édition : 06/2005
Liens
Voir d'autres articles du même numéro (6)
Voir la source
Indexation
- Thèmes : Autres applications des pompes à chaleur
- Mots-clés : Air; R22; Système biétage; Séchage; Pompe à chaleur; Performance; Experimentation; Évaporateur; Essai; COP
-
Effects of the ejector on the performances of a...
- Auteurs : PANG Z. Z., MA G. Y.
- Date : 20/05/2008
- Langues : Anglais
- Source : 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
Voir la fiche
-
Prestazioni di una pompa di calore ad aria: val...
- Auteurs : ROMAGNONI P., SCHIBUOLA L.
- Date : 06/1997
- Langues : Italien
- Source : Cond. Aria - vol. 41 - n. 6
Voir la fiche
-
High-temperature heat pump for resinous timber ...
- Auteurs : MINEA V.
- Date : 02/05/2005
- Langues : Anglais
- Source : 8th IEA Heat Pump Conference 2005: global advances in heat pump technology, applications, and markets. Conference proceedings [CD-ROM].
Voir la fiche
-
PERFORMANCE OF 5 PRACTICAL HEAT PUMP APPLICATIONS.
- Auteurs : JENSEN S. S.
- Date : 12/1989
- Langues : Anglais
- Source : H&V Eng. - vol. 62 - n. 698
Voir la fiche
-
Etude sur l'utilisation des pompes à chaleur po...
- Auteurs : TAKEUCHI R., SUN J., DOI M., YAMAMOTO H., HORIO H., KOJIMA H., TOYODA K.
- Date : 1991
- Langues : Japonais
- Source : J. Soc. agric. Struct. - vol. 22 - n. 2
Voir la fiche