Une étude de la performance de nouveaux frigorigènes à faible GWP pour l'utilisation dans le refroidissement évaporatif diphasique des systèmes électroniques.

Experimental performance investigation of new Low-GWP refrigerants for use in two-phase evaporative cooling of electronics.

Numéro : pap. 2371

Auteurs : NICOLETTE-BAKER A., GARR E., SATHE A., et al.

Résumé

With growing global warming concerns about current HFC refrigerants, a search for more environmentally-friendly fluids has begun. Potential alternatives to R134a should have significantly lower global warming potential (GWP), operate at similar system pressures, and maintain other chemical and physical property advantages of R134a.This study investigated four potential alternatives that have been identified by the Air-Conditioning, Heating, & Refrigeration Institute (AHRI) in its Low-GWP Alternative Refrigerants Evaluation Program. These refrigerants were R1234yf, R1234ze, N-13a (HDR-17), and N-13b (HDR-15). Each of these refrigerants was experimentally examined and compared to R134a in a two-phase pumped loop cooling system using a specifically designed test stand. This test stand included a liquid pump, an evaporator with a heating component, and an air-cooled condenser. For each test, refrigerant volume flow rate was varied to achieve the desired exit quality at a specified heat load while maintaining a constant amount of subcooling. The heat loads were varied from 500 W to 1000 W, while the exit quality ranged from 30% to 80%. R1234yf required substantial volume flow rate increases to achieve similar cooling effects as R134a; however, R1234ze, N-13a, and N-13b appeared to be much more viable solutions, due to smaller increases in volume flow rate required. A number of variables were examined to determine the thermal performance of each refrigerant, including heat sink surface temperatures, heat sink inlet and outlet refrigerant temperatures, and heat transfer coefficients. At 30% exit quality and a heat load of 500 W, R1234yf, R1234ze, N-13a, and N-13b required 33.13%, 13.14%, 12.54%, and 9.35% higher volume flow rates, respectively, compared with R134a. At 80% exit quality and 1000 W heat load, these differences were 36.65%, 13.61%, 15.12%, and 8.67%, respectively. Increases in required flow rates also resulted in higher pump power consumptions and increased system pressure drops compared with R134a.

Documents disponibles

Format PDF

Pages : 10 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental performance investigation of new Low-GWP refrigerants for use in two-phase evaporative cooling of electronics.
  • Identifiant de la fiche : 30012986
  • Langues : Anglais
  • Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 14/07/2014

Liens


Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence