Une pompe à solution à entraînement thermique pour les refroidisseurs à absorption de NH 3 /H 2 O.
A thermally driven solution pump for NH3/H2O-absorption chillers.
Auteurs : ARNITZ A., RIEBERER R.
Type d'article : Article, Article de la RIF
Résumé
The solution circulation in NH3/H2O-absorption chillers and heat pumps is mostly maintained with electrically driven solution pumps. An alternative to the use of electrical driving energy is the use of thermal driving energy which is supplied to the generator. This work discusses a concept of a thermally driven solution pump using refrigerant vapor from the generator to move the piston of a double-stroke membrane pump, the so called “DoublePump”. The “DoublePump”is designed to reach a pumping mass flow rate of 600 kg h-1 at predefined operating conditions of an absorption chiller. This requires the determination of the piston geometry and the size of the check and solenoid valves. The cooling capacity and efficiency of an absorption chiller operated with the “DoublePump”are reduced compared to the operation with an electrically driven solution pump. However, less electrical driving energy is required to operate the absorption chiller with the “DoublePump”.
Documents disponibles
Format PDF
Pages : 404–416
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A thermally driven solution pump for NH3/H2O-absorption chillers.
- Identifiant de la fiche : 30026600
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Date d'édition : 08/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.05.013
Liens
Voir d'autres articles du même numéro (50)
Voir la source
Indexation
-
Thèmes :
Refroidisseurs d'eau;
Systèmes à absorption et adsorption - Mots-clés : Conception; Refroidisseur; Ammoniac-eau; Absorption; Puissance frigorifique; Pompe; Modélisation; Membrane; COP
-
Einsatz gekühlter Membranabsorber in der Absorp...
- Auteurs : SCHAAL F., WEIMER T., HASSE H.
- Date : 16/11/2005
- Langues : Allemand
- Source : DKV-Tagungsbericht 2005, Würzburg./ 2005 Proceedings of the DKV Conference, Würzburg.
Voir la fiche
-
Prove di durata su un prototipo di pompa altern...
- Auteurs : CORALLO G.
- Date : 27/06/1997
- Langues : Italien
- Source : Le ultime tecnologie del freddo e del condizionamento./ Latest technologies in refrigeration and air conditioning.
Voir la fiche
-
Improving the performance of ammonia-water abso...
- Auteurs : IBRAHIM O. M., BARNETT S. M., BALAMURU V. G.
- Date : 1997
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche
-
Experimentelle Untersuchung gekühlter Membranab...
- Auteurs : SCHAAL F., WEIMER T., MATTES H., et al.
- Date : 21/11/2007
- Langues : Allemand
- Source : DKV-Tagungsbericht 2007, Hannover.
Voir la fiche
-
Analysis of high performance cycles for absorpt...
- Auteurs : LAZZARIN R. M., GASPARELLA A., LONGO G. A., et al.
- Date : 19/09/1999
- Langues : Anglais
- Source : 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
Voir la fiche