Document IIF
Amélioration des performances du refroidisseur à absorption de NH3-H2O avec un générateur combiné.
Performance improvement of NH3–H2O absorption chiller with a combined generator.
Auteurs : WIRTZ M., STUTZ B., PHAN H. T., BOUDÉHENN F.
Type d'article : Article de la RIF
Résumé
The present experimental work investigates the impact of an innovative falling-film and plate combined generator, associating vapor production and purification, on the performance of an NH3–H2O absorption chiller of 5-kW cooling capacity. The impact of the flooding of the lower part of the exchanger on the performance of the machine is investigated: It decreases the COP by 33% and cooling capacity by 38%. Solution sub-cooling at the combined generator inlet improves the purity of the ammonia vapor produced, but degrades the performance of the chiller. A design of experiments is defined to characterize the performance of the combined generator, which is highly impacted by the solution mass flowrate and concentration. Then, two correlation forms are used to predict the performance, and the adapted NTU model yields better results. Finally, for an air-conditioning application, a low solution mass flowrate allows the energy consumption to be reduced by approximately 15% but it requires a higher temperature for the heat source; while the increase in the solution mass flowrate degrades the performance but enables the machine to self-regulate at a low heat source.
Documents disponibles
Format PDF
Pages : 331-341
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance improvement of NH3–H2O absorption chiller with a combined generator.
- Identifiant de la fiche : 30030453
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 144
- Date d'édition : 12/2022
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.07.018
Liens
Voir d'autres articles du même numéro (32)
Voir la source
Indexation
-
Analyse de la simulation du cycle d'un système ...
- Auteurs : NAKAJIMA K., TAKEI T.
- Date : 10/2006
- Langues : Japonais
- Source : Refrigeration - vol. 81 - n. 948
Voir la fiche
-
Performance prediction of a two-bed solar adsor...
- Auteurs : UL QADIR N., SAID S. A. M., BEN-MANSOUR R.
- Date : 01/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 85
- Formats : PDF
Voir la fiche
-
THEORETICAL ANALYSIS OF AMMONIA-WATER ABSORPTIO...
- Auteurs : KAUSHIK S. C., BHARDWAJ S. C.
- Date : 07/1982
- Langues : Anglais
- Source : Int. J. Energy Res. - vol. 6 - n. 3
Voir la fiche
-
Energy and exergy analysis of an experimental N...
- Auteurs : COLORADO D., RIVERA W., CONDE-GUTIÉRREZ R. A., JIMÉNEZ-GARCÍA J. C.
- Date : 09/2024
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 165
- Formats : PDF
Voir la fiche
-
Simulation thermodynamique d'un climatiseur à a...
- Auteurs : BEN EZZINE N., SNOUSSI A., BELLAGI A., et al.
- Date : 09/2003
- Langues : Français
- Source : Rev. gén. Froid - vol. 92 - n. 1036
Voir la fiche